Description

SE655 Toroidal Conductivity Sensor | Fixed cable | PEEK | High chemical resistance

Universal and precise sensor with high chemical resistance over a very large measuring range, for heavily polluted media.

  • Sturdy design
  • Extremely large measuring range due to inductive measuring principle
  • Insensitive to contamination
  • No process-wetted electrodes
  • High chemical resistance (PEEK)
  • Steam-sterilizable
  • CIP-capable

Corrosion-resistant toroidal sensor for measuring pure water up to maximum conductivities. Smooth, easy-to-clean design. High accuracy due to electrodeless measurement. Low risk of contamination because of large sensor opening. Also for hazardous locations (SE655X).

Applications
Concentration measurement of acid and alkaline solutions, heavily polluted media, coating-forming and oil-containing media, salt spring, heavily polluted wastewaters, cooling water blowdown, concentrate monitoring, regeneration of ion exchangers

 

We look forward to hearing from you!
Contact Us

Technical details

Measurement Parameter: Conductivity (inductive)
Measurement error: ± (0.005 mS/cm + 0.5 % meas. value) | (- 20 ... 100 °C), ± (0.010 mS/cm + 0.5 % meas. value) | (> 100 °C)
Mounting: G ¾"
Measuring Range: 0 … 2,000 mS/cm
Explosion protection: No
Process Connection: G 3/4" (36-mm nut and FKM (Viton) gasket included in shipment)
Temperature: -20 … 125 °C
Temperature Detector: Pt100 (Class A)
Measuring principle: Inductive
Pressure: 0 … 20 bar
Material: PEEK
Cable: Fixed cable, 5 m
Protection: IP 68 (when mounted)
Cell factor: Approx. 2/cm (≥ 30 mm distance to wall)
Signal Transmission: analog

Downloads

Manuals

[2684] User Manual
SE655(X) / SE656(X) Toroidal Conductivity Sensors
Version 07

Brochures

[13395] Brochure
Sensors - For measuring pH/ORP, conductivity or oxygen. Digital or analog.

Data Sheets

[16722] Data sheet
SE655(X) Toroidal Conductivity Sensor
Product Description | Specifications | Product Range

Certificates

[14516] EU Declaration of Conformity (DE, EN, FR)
Analog Sensors, non Ex
No. EU250213A | 2025-02-13

Our service

Used in Process or Applications

The taste and quality of beer are highly dependent on the quality of the water used for brewing it. It is determined by pH and conductivity measurements.
Toxic sludge that must be treated for phosphorus recovery is produced in biological wastewater treatment plants.
Many measuring loops in pulp production are located in environments in which technical personnel must spend as little time as possible.

Related Products

Skip product gallery

Relevant Blog Posts

SE605H conductivity sensor with CondCheck: Integrated sockets for connecting a resistance decade

SE605H Conductivity Sensor with CondCheck

The SE605H conductivity sensor with CondCheck enables USP 645 verification without interrupting the measuring chain.

pH and conductivity measurement in vaccine production

Pharmaceutical contract manufacturer relies on Knick's transmitters for modular production plants for Covid-19 vaccines.

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

SE655X Digital and SE656X Digital - Digital Conductivity Sensors with Ex Certification

The SE655X digital and SE656X digital conductivity sensors with Memosens protocol are now also available with Ex certification.

New SE656N digital conductivity sensor

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

High-Precision Conductivity Measurement at Extreme Temperature Differences

Pharmaceutical manufacturer, EVER Pharma Jena uses the extremely robust conductivity sensors SE605(H) and SE680 with Memosens technology from Knick.