SE615 Conductivity Sensor | 2 Graphite electrodes | Memosens | 225 mm | For water and wastewater treatment

Reasonably priced sensor for water and wastewater treatment applications. 

  • Perfect galvanic isolation thanks to Memosens technology
  • No influence of humidity in the connector
  • Precalibration in the lab
  • Digital data transfer
  • Integrated sensor diagnostics
  • low maintenance
  • Integrated temperature detector
  • 2 graphite electrodes

Large measuring range thanks to electrodes made from low polarized special graphite. Designed for MemoRail applications. 

The SE615 conductivity sensor with Memosens connector system has 2 graphite electrodes and requires low maintenance. The integrated temperature detector provides automatic temperature compensation during calibration and operation of the sensor. The sensor is designed for simultaneous measurement of conductivity and temperature in industrial processes.

Applications
Water/wastewater treatment.

We look forward to hearing from you!
Contact Us

Technical details

Measurement Parameter:
Conductivity
Connector:
Memosens
Measuring Range:
10 µS/cm … 20 mS/cm
Length:
225 mm
Process Connection:
PG 13.5
Temperature:
–5 … 80 °C ( 23 ... 176 °F)
Temperature Detector:
NTC 30 kΩ
Body Material:
Polysulfone
Measuring principle:
2 electrodes
Pressure:
Max. 4 bar
Membrane material:
Graphite
Signal Transmission:
Memosens

Norms

Downloads

Manuals

[98688] User Manual (DE, EN, KO)
Memosens Cable CA/MS
Version 09
[4501] User Manual
SE615 Memosens 2-Electrode Sensor
Version 02

Brochures

[13209] Brochure
Memosens - The complete solution for smart sensor applications.
[13395] Brochure
Sensors - For measuring pH/ORP, conductivity or oxygen. Digital or analog.

Data Sheets

[2814] Data Sheet
SE615 Memosens 2-Electrode Sensor
Product Description | Specifications | Product Range

Certificates

[14511] EU Declaration of Conformity (DE, EN, FR)
No. EU260612A | 2026-06-12
Digital Sensors, non Ex
[14155] Declaration of Compliance 2.1 (DE, EN)
according to EN 10204 | gemäß EN 10204
O-Ringe aus EPDM oder Silikon | O-rings made of EPDM or Silicone
[18342] EU Declaration of Conformity (DE, EN, FR)
Memosens Measuring Cable Type CA/MS-***N**, CA/MS-***N**-L
No. EU231213H | 2023-12-13

Control Drawings

[14185] Control Drawing
Inductive Sensor-Cable Connection System Memosens
Zeichnungsnummer 214.410-240

Our service

Used in Process or Applications

Knick offers innovative process analyzers, high quality holders and fittings, and unique cleaning and calibration systems

Related Products

Skip product gallery
SE600 4-Electrode Conductivity Sensor | Fixed cable | For high pressure/high-temperature
SE600 4-Electrode Conductivity Sensor | Fixed cable | For high pressure/high-temperature
Product number:

SE600

Measuring Range: Approx. 0.5 µS/cm … 600 mS/cm

Process Connection: 1" weld-in socket

SE603 4-Electrode Conductivity Sensor | Fixed cable | Very high corrosion resistance
SE603 4-Electrode Conductivity Sensor | Fixed cable | Very high corrosion resistance
Product number:

SE603

Electrode Material: Platinum

Measuring Range: Approx. 0.5 µS/cm … 600 mS/cm

Process Connection: Special flange

SE604 2-Electrode Conductivity Sensor | 7-Pole | Measuring range from 1 nS/cm to 1000 μS/cm
SE604 2-Electrode Conductivity Sensor | 7-Pole | Measuring range from 1 nS/cm to 1000 μS/cm
Product number:

SE604

Electrode Material: Stainless steel 1.4571

Process Connection: Thread G1"

SE604 2-Electrode Conductivity Sensor | Memosens | Ex | Measuring range from ultrapure water to 500 μS/cm
SE604 2-Electrode Conductivity Sensor | Memosens | Ex | Measuring range from ultrapure water to 500 μS/cm
Product number:

SE604X-MS

Electrode Material: Stainless steel 1.4571

Measuring Range: 0.001 … 500 µS/cm

Process Connection: G 1"

SE604 2-Electrode Conductivity Sensor | Memosens | Measuring range from ultrapure water to 500 μS/cm
SE604 2-Electrode Conductivity Sensor | Memosens | Measuring range from ultrapure water to 500 μS/cm
Product number:

SE604-MS

Electrode Material: Stainless steel 1.4571

Measuring Range: 0.001 … 500 µS/cm

Process Connection: G 1"

SE605H 2-Electrode Conductivity Sensor | Memosens | Ingold socket | Hygienic design
SE605H 2-Electrode Conductivity Sensor | Memosens | Ingold socket | Hygienic design
Product number:

SE605H-NMSH

Measuring Range: 0 … 1,000 µS/cm

Process Connection: Ingold socket

SE610 2-Electrode Conductivity Sensor | Fixed cable | For measuring low conductivities in water
SE610 2-Electrode Conductivity Sensor | Fixed cable | For measuring low conductivities in water
Product number:

SE610

Electrode Material: Stainless steel 1.4571

Measuring Range: 0.1 … 1,000 µS/cm

Process Connection: Thread G1/2"

SE615 Conductivity Sensor | 2 Graphite electrodes | Memosens | 120 mm | For water and wastewater treatment
SE615 Conductivity Sensor | 2 Graphite electrodes | Memosens | 120 mm | For water and wastewater treatment
Product number:

SE615/1-MS

Measuring Range: 10 µS/cm … 20 mS/cm

Process Connection: PG 13.5

SE615 Conductivity Sensor | 2 Graphite electrodes | Memosens | 225 mm | For water and wastewater treatment
SE615 Conductivity Sensor | 2 Graphite electrodes | Memosens | 225 mm | For water and wastewater treatment
Product number:

SE615/2-MS

Measuring Range: 10 µS/cm … 20 mS/cm

Process Connection: PG 13.5

SE620 2-Electrode Conductivity Sensor | VP | Pharma compliant hygienic design
SE620 2-Electrode Conductivity Sensor | VP | Pharma compliant hygienic design
Product number:

SE620/1

Electrode Material: Stainless steel 1.4435

Measuring Range: 0 … 50 µS/cm

Process Connection: Clamp DN 25