Skip to main content Skip to search Skip to main navigation

SE656 Toroidal Conductivity Sensor | Memosens | Fixed cable | PFA | Resistant to highly oxidizing media

Description

SE656 Toroidal Conductivity Sensor | Memosens | Fixed cable | PFA | Resistant to highly oxidizing media

Universal and precise conductivity sensor with maximum chemical resistance to highly oxidizing media. Digital with Memosens protocol.

  • Process-wetted material: PFA
  • Sturdy design
  • Resistant to contamination and fouling
  • Range of six decades
  • Inductive measuring principle, full galvanic isolation of sensor coils from process medium
  • Digital with Memosens protocol

The SE656N digital toroidal conductivity sensor is a sturdy and corrosion-resistant sensor that, thanks to its high chemical resistance and durability when exposed to aggressive media, is particularly suitable for applications in the chemical industry.

A combination of a large sensor opening and dirt-repellent material prevents blockages and deposits in media with a high pollution degree. The inductive measuring principle enables full galvanic isolation of the measurement from the medium. 

The sensor is an all-rounder, suitable for a multitude of applications with a range covering six decades. Equipped with Memosens protocol as a digital version, it offers considerable process and data security, and ensures reliable data recording. Also for hazardous areas (SE656X -GEFTW0KM). 

Applications
Concentration measurement, in particular of highly oxidizing acids and bases, online quality monitoring of chemical products in tanks and pipes, phase separation of product mixtures, paper manufacturing (high fiber concentration), heavily soiled media and wastewater, fouling media.

New SE656N digital conductivity sensor

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

We look forward to hearing from you!
Contact Us

Technical details

Measurement Parameter: Conductivity (inductive)
Measurement error: ± (0.005 mS/cm + 0.5 % meas. value) | (- 20 ... 100 °C), ± (0.010 mS/cm + 0.5 % meas. value) | (> 100 °C)
Measuring Range: 0 … 2,000 mS/cm
Explosion protection: No
Process Connection: G3/4“ (Union nut A/F36 and FFKM (Chemraz) seal included in package contents)
Measuring principle: Inductive
Relative process pressure: 0 ... 16 bar (see Pressure/Temperature Diagram)
Cable: Fixed cable, 7 m
Fixed cables with ferrules: 7 m
Protection: IP 68 (sensor mounted, with original gasket / EN 60529)
Temperature response time t90: Approx. 11 min
Ambient temperature: –20 ... 60 °C
Storage temperature: –20 ... 80 °C
Cell factor: 1.98/cm (≥ 30 mm distance to wall)
Signal Transmission: Memosens Protocol
Resolution: 0.002 μS/cm

Downloads

Manuals

[18350] User Manual
SE655/SE656
Toroidal Conductivity Sensor
Version 05

Brochures

[13395] Brochure
Sensors - For measuring pH/ORP, conductivity or oxygen. Digital or analog.

Data Sheets

[16575] Data sheet
SE656(N/X) Toroidal Conductivity Sensor
Product Description | Specifications | Product Range

Our service

Used in Process or Applications

Toxic sludge that must be treated for phosphorus recovery is produced in biological wastewater treatment plants.

Related Products

Skip product gallery
SE600 4-Electrode Conductivity Sensor | Fixed cable | For high pressure/high-temperature
SE600 4-Electrode Conductivity Sensor | Fixed cable | For high pressure/high-temperature

Measuring Range: Approx. 0.5 µS/cm … 600 mS/cm

Process Connection: 1" weld-in socket

SE603 4-Electrode Conductivity Sensor | Fixed cable | Very high corrosion resistance
SE603 4-Electrode Conductivity Sensor | Fixed cable | Very high corrosion resistance

Electrode Material: Platinum

Measuring Range: Approx. 0.5 µS/cm … 600 mS/cm

Process Connection: Special flange

SE604 2-Electrode Conductivity Sensor | 7-Pole | Measuring range from 1 nS/cm to 1000 μS/cm
SE604 2-Electrode Conductivity Sensor | 7-Pole | Measuring range from 1 nS/cm to 1000 μS/cm

Electrode Material: Stainless steel 1.4571

Process Connection: Thread G1"

SE604 2-Electrode Conductivity Sensor | Memosens | Ex | Measuring range from ultrapure water to 500 μS/cm
SE604 2-Electrode Conductivity Sensor | Memosens | Ex | Measuring range from ultrapure water to 500 μS/cm

Electrode Material: Stainless steel 1.4571

Measuring Range: 0.001 … 500 µS/cm

Process Connection: G 1"

SE604 2-Electrode Conductivity Sensor | Memosens | Measuring range from ultrapure water to 500 μS/cm
SE604 2-Electrode Conductivity Sensor | Memosens | Measuring range from ultrapure water to 500 μS/cm

Electrode Material: Stainless steel 1.4571

Measuring Range: 0.001 … 500 µS/cm

Process Connection: G 1"

SE605H 2-Electrode Conductivity Sensor | Memosens | Ingold socket | Hygienic design
SE605H 2-Electrode Conductivity Sensor | Memosens | Ingold socket | Hygienic design

Measuring Range: 0 … 1,000 µS/cm

Process Connection: Ingold socket

SE610 2-Electrode Conductivity Sensor | Fixed cable | For measuring low conductivities in water
SE610 2-Electrode Conductivity Sensor | Fixed cable | For measuring low conductivities in water

Electrode Material: Stainless steel 1.4571

Measuring Range: 0.1 … 1,000 µS/cm

Process Connection: Thread G1/2"

SE620 2-Electrode Conductivity Sensor | VP | Pharma compliant hygienic design
SE620 2-Electrode Conductivity Sensor | VP | Pharma compliant hygienic design

Electrode Material: Stainless steel 1.4435

Measuring Range: 0 … 50 µS/cm

Process Connection: Clamp DN 25