P45000 High Voltage Transducer / Transmitter | SIL 2/SIL 3 Functional Safety
Description
High-voltage transducer with certification for SIL 2 / SIL 3
- Measurement up to 4500 V DC and 3000 V AC
- Reinforced insulation: up to 3700 V AC/ 4800 V DC
- Test voltage: 20 kV AC
- Suitable for applications with functional safety up to SIL 2 / SIL 3
- Space-saving, especially with stacked mounting
- Flexible mounting: vertical/horizontal with bolt, or DIN rail
- Optional partition extends voltage creepage clearance
- Withstands harsh environments due to full vacuum encapsulation
- Certified for use on rolling stock according to EN 50155
- For all DC and AC driven rolling stock, including diesel-electric vehicles
- Proven usage in industrial applications with stringent safety requirements
- Solution for safe monitoring of hydrogen electrolyzers and fuel cells
- 5-year warranty
The P45000-series transducers are designed for measuring high DC and AC voltages, especially in critical environments where its SIL2/ SIL3 certification helps to ensure functional safety. Application examples include the control of traction motors on rolling stock, safe monitoring of hydrogen electrolyzers and fuel cells, and the electrical safeguarding of potentially dangerous plant floor manufacturing and testing areas.
The voltage measurement input is highly isolated from output and auxiliary power. The current output is compatible with commercially available control inputs.
The housing offers flexible mounting options: upright or horizontal, screwed or snapped onto 35 mm DIN rails. The devices can even be mounted in a stack, allowing for very tight space requirements.
For the first time, applications with functional safety requirements can be properly carried out. The high-voltage transmitter is certified for use in SIL2 systems, and SIL3 can be achieved in a redundant configuration. Thus, for example, the presence of dangerously high voltages can be reliably and safely detected.
Innovations at InnoTrans 2024 for rolling stock and DC traction power supply
Sept 2024
Interface Technology
We look forward to hearing from you!
Contact Us
Function: | High voltage measurement |
---|---|
Input: | 0 ... (±)500 V, 0 ... (±)750 V, 0 ... (±)1000 V, 0 ... (±)1500 V, 0 ... (±)2000 V, 0 ... (±)2800 V, 0 ... (±)3000 V, Overrange up to 150 % |
Output: | 0 … ±50 mA, 0 … ±50 mA, 4 ... 20 mA |
Isolation AC/DC: | 4,800 V DC, up to 3,600 V AC |
Test Voltage: | 10/18 kV AC |
Power Supply: | ±15 ... ±24 V DC |
Cutoff Frequency: | Cutoff frequency 10 kHz; lower cutoff frequencies on request |
Ambient operating temperature: | –40 ... 85 °C |
Dimensions (W x L x H): | 28 x 148 x 128.5 mm |
Special features: | DIN rail and wall mounting options, For use in SIL2 systems and, redundantly, SIL3 (IEC 61508), For use on rolling stock (EN 50155), HV input with fixed cables or screw terminals, Optimized for low space demand, Stackable, Very compact |
Standards: | EN 50155:2021 |
Product Category: | High Voltage Transducer |