Skip to main content

P29000 High Voltage Transducer / Transmitter | Calibrated and Switchable

Description

P29000 High Voltage Transducer / Transmitter | Calibrated and Switchable

Compact high-voltage isolation amplifiers with safe galvanic isolation, broad-range power supply and genuine calibrated range selection.

  • Universal usability, input 20 mV to 1000 V
  • Working voltages up to 1000 V AC/DC
  • Protective separation according to EN 61140 – protection of the maintenance staff and subsequent devices against excessively high voltages up to 600 V AC/DC
  • Test voltage 5.4 kV AC across input and output
  • Excellent transmission propertie
    • Gain error 0.2 %
    • Cutoff frequency > 10 kHz
    • Response time T99 < 200 µs
    • High output power: 12 V (current output), 10 mA (voltage output)"
  • High immunity to transient common-mode interference (T-CMR >100 dB)
  • Tremendous flexibility provided by calibrated range selection; reduced number of product variants minimizes inventory costs
  • Optional sensor adjustment with zero point potentiometer
  • Worldwide usability with broad-range power supply 20 V to 230 V AC/DC ±10 %; reliable function even with unstable supply
  • No damage in the case of erroneous power connection
  • Passive current output: additional passive current output allows for connection of active PLC inputs
  • Switchable inversion of the output
  • RangeLimit: adjustable lower or upper limit at output; optional
  • Test jacks for measuring output current and voltage
  • Low space requirement in enclosure with only 17.5 mm wide modular housing
  • Low-cost assembly: Quick mounting, convenient connection of the power supply via DIN rail bus connectors (in the case of 24 V DC supply)
  • 5-year warranty

Working voltages up to 1000 V AC/DC and test voltages up to 5.4 kV AC, maximum performance in a compact modular housing.

High-voltage P29000 series isolation amplifiers are available in two input versions for a variety of requirements: high voltage, mV. The devices are ideal for monitoring and controlling electrical drive systems operated with DC voltages and feature a passive output for direct connection to a supplying PLC. Input voltages from ±100 V to ±1000 V DC are galvanically isolated and provided at the output as standard 0/4 … 20 mA or 0 …. 10 V signals or as a bipolar signal in the range of -20 … 20 mA or -10 … 10 V.

Typical applications are DC current and servo drives, generators etc, as well as power supplies for welding units and inverters for solar or wind power systems. The extraordinary performance and flexibility of the isolation amplifiers supports the user in the development of the most diverse products or system solutions.

We look forward to hearing from you!
Contact Us

Technical details

Function: Current measurement via shunt resistor, Voltage measurement
Input: 0 ... (±)30 mV up to 0 ... (±)100 V, 0 ... (±)100 V up to 0 ... (±)1000 V
Output: 0 ... (±)10 V, 0 ... (±)20 mA, 4 ... 20 mA, passive 4 ... 20 mA
Isolation AC/DC: up to 1,000 V
Test Voltage: 5.4 kV AC
Power Supply: 24 ... 230 V AC/DC
Cutoff Frequency: Switchable cutoff frequency 10 kHz or 10 Hz, other cutoff frequency on request
Ambient operating temperature: –25 ... 70 °C
Dimensions (W x L x H): 17.5 x 99 x 114.5 mm
Special features: Measuring ranges adjusted via DIP switches, a passive current output allows for connection to active PLC inputs
Standards: UL 61010-1, UL 61010-2-030
Product Category: High Voltage Transducer, Isolated Signal Conditioner

Downloads

Manuals

[14495] User Manual (DE, EN, FR)
VariTrans P2900*P2
Version 03

Brochures

[18000] Brochure
Precision Devices for the Rail Industry

Data Sheets

[1323] Data sheet
P29000 Transducers for High Voltage / Shunt Applications
Product Description | Specifications | Product Range

Certificates

[14281] EU Declaration of Conformity (DE, EN, FR)
No. EU220121C | 2022-01-21
VariTrans P29000
[11729] Certificate of Compliance (UL)
High-Voltage isolation amplifiers
P2900*P2/00..., P2900*P2/01..., BL590, BL591
ZT231124E

Software

[11876] Knick Produktmakros (.pdf)
ePLAN Electric P8
[12154] Software (.zip)
ePLAN P8 Produktmakros

Servizio Unser

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

Used in Process or Applications

The production process of HV heaters involves many steps, with some of them being manual. Various tests are carried out in-line, according to the corresponding manufacturing stages.

Related Products

Relevant Blog Posts

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

Successful joint project : Knick developed the special Ceramat WA 155 retractable fitting for optical probes from SOPAT

In cooperation with SOPAT, Knick developed a special Ceramat fitting for optical probes for automatic cleaning in fouling processes.

High-quality immersion fitting for mobile applications

ARD 170 enables measurements even in deep water

Modular immersion fitting as an electrically conductive variant

Knick is expanding its portfolio of fittings for liquid analysis with additional electrically conductive (EL) variants.

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.