Skip to main content

P43000 TRMS AC/DC High Voltage Transducer / Transmitter

Description

P43000 TRMS AC/DC High Voltage Transducer / Transmitter
  • Universal usability:
    • AC input 100 mA~ to 5 A~
    • DC output 0 (4) … 20 mA, 0 … 10 V
  • Working voltages up to 3600 V AC/DC
  • TransShield technology
    allows for extremely compact modular housing
  • Protection against electric shock 
    through protective separation up to 1800 V AC /DC according to EN 61140
  • Test voltages up to 15 kV AC
  • Outstanding transmission properties:
    • Gain error < 0.5 % with crest factor < 3
    • Gain error < 1 % with crest factor 3 … 5
    • Response time T90
  • Virtually no influence from common-mode voltages:
    CMRR approx. 150 dB
  • Tremendous flexibility thanks to:
    • calibrated switching of up to 16 input/output ranges
    • up to 16 customer-specific ranges
    • VariPower broad-range power supply 20 V to 253 V AC/DC
  • Reliable function even with unstable supply
  • No damage
    in the case of erroneous power connection
  • Switchable models
    reduce variety of versions, thus saving storage costs
  • Robust
    thanks to vacuum encapsulation
  • Mechanically stable
    for operation on ships, trains and vehicles
  • 5-year warranty

The P43000 TRMS isolation amplifiers have been specially conceived for measurements of bipolar currents ranging from milliamps up to 5 amps. They reliably isolate high potentials at the input circuit. Thanks to the true rms conversion in the transducer, even distorted input signals are captured correctly and output as so-called true rms values.


The isolating distances are designed to withstand permanent voltages up to 3600 V AC/DC and fast transients up to 20 kV.

We look forward to hearing from you!
Contact Us

Technical details

Function: True-RMS of AC currents
Input: 0 ... 5 A AC, 0 ... 100 mA AC
Output: 0 ... (±)10 V, 0 ... (±)20 mA, 4 ... 20 mA, peak or TRMS values
Isolation AC/DC: up to 3,600 V
Test Voltage: 10/15 kV AC
Power Supply: 22 ... 230 V AC/DC
Cutoff Frequency: Cutoff frequency 5 kHz, lower cutoff frequency on request
Ambient operating temperature: –10 ... 70 °C, –40 ... 75/85 °C
Dimensions (W x L x H): 45 x 90 x 118 mm (D2)
Special features: Exceptionally high MTBF of 2165 years (Mean Time Between Failures), based on field data, Switchable or customized versions
Product Category: High Voltage Transducer

Downloads

Manuals

[17399] User Manual
P43000 TRMS
Version 06

Brochures

[14160] Brochure
Product Overview Interface Technology

Data Sheets

[1615] Data sheet
P43000 TRMS
Product Description | Specifications | Product Range

Certificates

[11463] EU Declaration of Conformity (DE, EN, FR)
Series VariTrans P4x000 (D*-nnnn/D*AG-nnnn/D*TRMS-nnnn)
No. EU221209A | 2023-11-29
[12429] EU Declaration of Conformity (DE, EN, FR)
P4*000 KTA
No. EU230522A | 2023-12-12
[14140] Quality Report (MTBF)
Document No. TX180416A
Failure Rate of Series P40000

Software

[11876] Knick Produktmakros (.pdf)
ePLAN Electric P8
[12154] Software (.zip)
ePLAN P8 Produktmakros

Our service

Used in Process or Applications

Relevant Blog Posts

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

Successful joint project : Knick developed the special Ceramat WA 155 retractable fitting for optical probes from SOPAT

In cooperation with SOPAT, Knick developed a special Ceramat fitting for optical probes for automatic cleaning in fouling processes.

High-quality immersion fitting for mobile applications

ARD 170 enables measurements even in deep water

Modular immersion fitting as an electrically conductive variant

Knick is expanding its portfolio of fittings for liquid analysis with additional electrically conductive (EL) variants.

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.