P42000 TRMS AC/DC High Voltage Transducer | Input up to ±3600 V | True RMS measurement
Product number:
P42000TRMS
Description
P42000 TRMS AC/DC High Voltage Transducer | Input up to ±3600 V | True RMS measurement
AC/DC high voltage transducers for true rms measurement Input voltages up to Vin = 3600 V AC
- Universal usability:
- AC input 60 mV~ up to 3600 V~ as well as 100 mA~ up to 5 A~
- DC output 0 (4) … 20 mA, 0 … 10 V
- TransShield technology
enables extremely compact modular housings - Working voltages up to 3600 V AC/DC
- Protection against electric shock
with protective separation up to 1800 V AC/DC according to EN 61140 - Test voltages up to 15 kV AC
- Excellent transmission properties:
- Gain error Crest factor ≤ 3 < 0.5 %
- Gain error Crest factor 3 … 5 < 1 %
- Response time T90 < 150 ms
- Virtually no influence from common-mode voltages:
CMRR approx. 150 dB - Tremendous flexibility provided by
- Calibrated switching of up to 16 input/output ranges
- up to 16 customer-specific measuring ranges
- VariPower 20 V to 253 V AC/DC broad-range power supply
- Reliable function even with unstable supply
- No damage
in the case of erroneous power connection - Switchable models
minimize required device variants and save stockkeeping costs - Robust
thanks to vacuum encapsulation - Mechanically stable
for operation on ships, rail vehicles and land crafts - 5-year warranty
The P42000 TRMS isolation amplifiers have been specially conceived for measuring high voltages up to 3600 V AC/DC. They reliably isolate high potentials at the input circuit. Thanks to the true rms conversion in the transducer, even distorted input signals are captured correctly and output as so-called true rms values.
The isolating distances are designed to withstand permanent voltages up to 3600 V AC/DC and fast transients up to 20 kV.
We look forward to hearing from you!
Contact Us
Input: | 0 ... 10 V AC, 0 ... 3600 V AC |
---|---|
Output: | 0 ... (±)10 V, 0 ... (±)20 mA, 4 ... 20 mA, peak or TRMS values |
Isolation AC/DC: | 2,200 V, up to 3,600 V |
Test Voltage: | 10/15 kV AC |
Power Supply: | 22 ... 230 V AC/DC |
Cutoff Frequency: | Cutoff frequency 5 kHz, lower cutoff frequency on request |
Ambient operating temperature: | –10 ... 70 °C |
Dimensions (W x L x H): | 45 x 90 x 118 mm (D2), 67.5 x 90 x 118 mm (D3) |
Special features: | Exceptionally high MTBF of 2165 years (Mean Time Between Failures), based on field data, High isolation in a compact housing, Switchable (16 input/output signal combinations) or customized versions |
Product Category: | High Voltage Transducer |