Skip to main content

SE707 Oxygen Sensor | Memosens | 220 mm | Ex | Measuring range (resolution) 0 ... 50 mg/l (1 μg/l)

Description

SE707 Oxygen Sensor | Memosens | 220 mm | Ex | Measuring range (resolution) 0 ... 50 mg/l (1 μg/l)

Reliable measurement of oxygen traces, also under sterile and hygienic conditions; signal-stable and robust, digital, with Memosens technology.

  • perfect galvanic isolation thanks to Memosens technology
  • precalibration in the lab
  • no influence of humidity in the connector
  • digital data transfer
  • integrated sensor diagnostics
  • high level of process safety
  • durable materials
  • robust design
  • easy to clean thanks to extremely smooth surface
  • very simple calibration in air without calibration gases
  • very high resolution of 1 ppb in the trace range
  • cost-efficient service due to easy-to-replace membrane module and interior body
  • hygienic design
  • low cross-sensitivity to CO2
  • operation also in hazardous locations

High resolution of low oxygen concentrations, simple and cost-efficient sensor calibration in ambient air. No calibration gases. High signal stability, also in the presence of high CO2 partial pressures.

FDA-conforming material with extremely smooth polished surface. Simple maintenance due to modular design. Sterilizable, autoclavable, and CIP capable. Also suitable for hazardous locations.

Applications
Beverage filling (e.g. milk, beer), measurement in boiler feed water (detection limit 1 ppb)

We look forward to hearing from you!
Contact Us

Technical details

Measurement Parameter: Oxygen
Perm. temp range (measurement): 0 ... 80 °C
Permissible pressure range (measurement): 0.2 ... 6 bar absolute
Connector: Memosens
Explosion protection: Ex
Length: 220 mm
Measuring Range: pO₂ < 1200 mbar
Temperature Detector: NTC 22 kΩ
Measuring Principle: Amperometric
Membrane material: PTFE/silicone/PTFE, FDA compliant (reinforced with steel mesh)
Flow dependence: ≤ 5 %
Signal Transmission: digital
Mechanical pressure resistance: Max. 12 bar absolute
Temperature range (stability): –5 ... +121 °C (steam sterilizable/autoclavable)
Accuracy: 1 % + 1 ppb (1 % + 3 ppb in liquids containing CO₂)
Signal in ambient air: 290 … 500 nA
Response time at 25 °C (air –> N2): 98 % full scale < 90 s
Residual signal in O₂-free medium: ≤ 0.1% of signal in ambient air | In CO2: ≤ 0.01% of signal in ambient air
O-ring material (process-wetted): silicone (FDA & USP Class VI tested)
Process-wetted sensor parts: Stainless steel 1.4404 (material certificate 3.1B)
Surface roughness: N 5 (RA < 0.4 μm)
Interior body incl. electrodes: replaceable (ZU 0568)
Detection limit: 1 ppb (3 ppb in liquids containing CO₂)

Downloads

Manuals

[17422] User Manual
SE707 Memosens
incl. Ex Approval Japan (JPEx DEK19.0046X)
Version 04
[3105] User Manual
SE707 Memosens Oxygen Sensor
Version 04
[16286] User Manual (DE, EN, KO)
Memosens Cable CA/MS
Version 09

Brochures

[13395] Brochure
Sensors - For measuring pH/ORP, conductivity or oxygen. Digital or analog.

Data Sheets

[3096] Data sheet
SE707 Memosens Oxygen Sensor
Product Description | Specifications | Product Range
[10145] Data sheet
Accessories for Sensors for Oxygen Measurement
Product Description | Specifications | Product Range

Certificates

[16639] Type Approval Certificate for Ex-Equipment (JA)
No. DEK19.0046X, Issue No. 0 (Japan)
SE5**X/*-*MSN | SE7**X/*-*MSN
[14685] Certificate of Conformity (FM)
No. FM17US0208X | 2019-05-27 | USA
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[11064] EU Declaration of Conformity
No. EU210427A | 2021-04-27
Memosens Sensors | Types SE 5..X..-.MS., SE604X-MS**, SE605….., SE6**X**MS, SE7**…
[12902] Confirmation / Bestätigung
Series SE706X/*-NMSN, SE707X/*-NMSN
No components of animal origin / Kein tierischer Ursprung
[12826] EU-Type Examination Certificate (DEKRA)
Nr. BVS 16 ATEX E 037 X | 2024-02-20
Memosens-Ex-Sensors
[14155] Declaration of Compliance 2.1 (DE, EN)
according to EN 10204 | gemäß EN 10204

Control Drawings

[14185] Control Drawing
Inductive Sensor-Cable Connection System Memosens
Zeichnungsnummer 214.410-240

Our service

Used in Process or Applications

Since steam generators fulfill application-critical functions and the cost of their downtime or replacement is extremely high, damage caused by wear should be prevented by monitoring water quality.

Related Products

Relevant Blog Posts

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

SE655X Digital and SE656X Digital - Digital Conductivity Sensors with Ex Certification

The SE655X digital and SE656X digital conductivity sensors with Memosens protocol are now also available with Ex certification.

New SE656N digital conductivity sensor

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

How to get the sensor into the process