Skip to main content Skip to search Skip to main navigation

SE605H 2-Electrode Conductivity Sensor | Memosens | Clamp | Hygienic design

Description

SE605H 2-Electrode Conductivity Sensor | Memosens | Clamp | Hygienic design

Robust 2-electrode sensor, for precise and reliable measurement of low and very low conductivities, particularly in ultrapure water, digital, with Memosens technology

  • Perfect galvanic isolation thanks to Memosens technology
  • Digital data transfer
  • Integrated sensor diagnostics
  • Large measuring range from ultrapure water to 1000 μS/cm
  • Hygienic design
  • Electropolished – Roughness Ra ≤ 0.4 or ≤ 0.8 μm
  • FDA-certified materials
  • Coaxially arranged electrodes
  • Independent of installation conditions
  • Integrated temperature detector
  • High level of process safety due to durable materials and robust design
  • Easy to clean thanks to replaceable outer and inner electrode
  • Particularly suitable for monitoring ultrapure water in power plants
  • Replaceable gaskets

Robust sensor with hygienic design made of stainless steel in coaxial arrangement. Large measuring range from ultrapure water to 1000 μS/cm. Integrated temperature detector for temperature compensation. Easy to clean thanks to replaceable outer and inner electrode.

Applications
Ultrapure water, WFI (water for injection), pharmaceutical and food industry, biotechnology

SE605H Conductivity Sensor with CondCheck

The SE605H conductivity sensor with CondCheck enables USP 645 verification without interrupting the measuring chain.

We look forward to hearing from you!
Contact Us

Technical details

Measurement Parameter:
Conductivity
Connector:
Memosens
Measuring Range:
0 … 1,000 µS/cm
Explosion protection:
No
Process Connection:
Clamp 1 1/2"
Temperature Detector:
NTC 30 kΩ
Pressure:
Max. 10 bar (135 °C)
Max. 16 bar (–10 … 110 °C)
Wetted materials:
Stainless steel 1.4435; isolator PEEK; seals: see product line
Cell constant:
0.021/cm

Norms

Downloads

Manuals

[2776] User Manual
SE605H Conductivity Sensor
Version 09

Brochures

[13209] Brochure
Memosens - The complete solution for smart sensor applications.
[13395] Brochure
Sensors - For measuring pH/ORP, conductivity or oxygen. Digital or analog.

Data Sheets

[103670] Data Sheet
SE605H pharma
Product Description | Specifications | Product Range
Version 01

Certificates

[14685] Certificate of Conformity (FM)
No. FM17US0208X | 2019-05-27 | USA
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[14511] EU Declaration of Conformity (DE, EN, FR)
No. EU260612A | 2026-06-12
Digital Sensors, non Ex
[18342] EU Declaration of Conformity (DE, EN, FR)
Memosens Measuring Cable Type CA/MS-***N**, CA/MS-***N**-L
No. EU231213H | 2023-12-13
[16292] Korean safety certificate Kosha (KO)
No. 2020-KA4BO-0368X
Measuring Cable CA/MS

Our service

Used in Process or Applications

Knick offers innovative process analyzers, high quality holders and fittings, and unique cleaning and calibration systems

Related Products

Skip product gallery
SE600 4-Electrode Conductivity Sensor | Fixed cable | For high pressure/high-temperature
SE600 4-Electrode Conductivity Sensor | Fixed cable | For high pressure/high-temperature
Product number:

SE600

Measuring Range: Approx. 0.5 µS/cm … 600 mS/cm

Process Connection: 1" weld-in socket

SE603 4-Electrode Conductivity Sensor | Fixed cable | Very high corrosion resistance
SE603 4-Electrode Conductivity Sensor | Fixed cable | Very high corrosion resistance
Product number:

SE603

Electrode Material: Platinum

Measuring Range: Approx. 0.5 µS/cm … 600 mS/cm

Process Connection: Special flange

SE604 2-Electrode Conductivity Sensor | 7-Pole | Measuring range from 1 nS/cm to 1000 μS/cm
SE604 2-Electrode Conductivity Sensor | 7-Pole | Measuring range from 1 nS/cm to 1000 μS/cm
Product number:

SE604

Electrode Material: Stainless steel 1.4571

Process Connection: Thread G1"

SE604 2-Electrode Conductivity Sensor | Memosens | Ex | Measuring range from ultrapure water to 500 μS/cm
SE604 2-Electrode Conductivity Sensor | Memosens | Ex | Measuring range from ultrapure water to 500 μS/cm
Product number:

SE604X-MS

Electrode Material: Stainless steel 1.4571

Measuring Range: 0.001 … 500 µS/cm

Process Connection: G 1"

SE604 2-Electrode Conductivity Sensor | Memosens | Measuring range from ultrapure water to 500 μS/cm
SE604 2-Electrode Conductivity Sensor | Memosens | Measuring range from ultrapure water to 500 μS/cm
Product number:

SE604-MS

Electrode Material: Stainless steel 1.4571

Measuring Range: 0.001 … 500 µS/cm

Process Connection: G 1"

SE605H 2-Electrode Conductivity Sensor | Memosens | Ingold socket | Hygienic design
SE605H 2-Electrode Conductivity Sensor | Memosens | Ingold socket | Hygienic design
Product number:

SE605H-NMSH

Measuring Range: 0 … 1,000 µS/cm

Process Connection: Ingold socket

SE610 2-Electrode Conductivity Sensor | Fixed cable | For measuring low conductivities in water
SE610 2-Electrode Conductivity Sensor | Fixed cable | For measuring low conductivities in water
Product number:

SE610

Electrode Material: Stainless steel 1.4571

Measuring Range: 0.1 … 1,000 µS/cm

Process Connection: Thread G1/2"

SE615 Conductivity Sensor | 2 Graphite electrodes | Memosens | 120 mm | For water and wastewater treatment
SE615 Conductivity Sensor | 2 Graphite electrodes | Memosens | 120 mm | For water and wastewater treatment
Product number:

SE615/1-MS

Measuring Range: 10 µS/cm … 20 mS/cm

Process Connection: PG 13.5

SE615 Conductivity Sensor | 2 Graphite electrodes | Memosens | 225 mm | For water and wastewater treatment
SE615 Conductivity Sensor | 2 Graphite electrodes | Memosens | 225 mm | For water and wastewater treatment
Product number:

SE615/2-MS

Measuring Range: 10 µS/cm … 20 mS/cm

Process Connection: PG 13.5

SE620 2-Electrode Conductivity Sensor | VP | Pharma compliant hygienic design
SE620 2-Electrode Conductivity Sensor | VP | Pharma compliant hygienic design
Product number:

SE620/1

Electrode Material: Stainless steel 1.4435

Measuring Range: 0 … 50 µS/cm

Process Connection: Clamp DN 25