Skip to main content Skip to search Skip to main navigation

A20340 Standard-signal Multiplier | 6-Port Isolation

Description

A20340 Standard-signal Multiplier | 6-Port Isolation

Signal multiplier with four calibrated outputs, also for applications with high output loads.

  • Safety in the smallest space
    6-port isolation in 22.5 mm modular housing
  • Signal multiplication
    combined with signal conversion
  • Load increase
    up to 1000 ohms possible for inputs with high input impedances
  • Standards-compliant personal protection
    through protective separation according to EN 61140
  • Precise signal reproduction
    thanks to a short response time of T90 = 1 ms, even dynamic signal changes are accurately reproduced
  • Low-cost solution
    only one compact, low-cost device is required instead of four conventional signal conditioners

The A20340 signal multiplier is an extremely compact product that also provides a cost-effective solution to the problem. In this module, the input, all 4 outputs, and the power supply are safely decoupled from one another (six-port isolation).

In addition to “quadrupling” the analog signal, the A20340 is capable of calibrated signal transmission with signal isolation.

We look forward to hearing from you!
Contact Us

Technical details

Function: Decoupled distribution of standard signals
Input: 0 ... 20 mA, 4 ... 20 mA
Output: 0 ... 20 mA, 4 ... 20 mA
Isolation AC/DC: up to 300 V
Test Voltage: 2.5 kV AC
Power Supply: 24 V DC
Ambient operating temperature: 0 … 55 °C
Dimensions (W x L x H): 6.2 x 93 x 101 mm
Special features: All ports galvanically decoupled (6-port isolation), Signal quadrupler with calibrated inputs and 4 outputs, each driving full loads up to 500 ohms
Product Category: Signal Multiplier

Downloads

Manuals

[16589] User Manual (DE, EN, ZH)
A20340P3
Version 02

Brochures

[14160] Brochure
Product Overview Interface Technology

Data Sheets

[16583] Data Sheet
A20340
Product Description | Specifications | Product Range

Certificates

[11272] EU Declaration of Conformity (DE, EN, FR)
No. EU220125I | 2022-01-25
A20300P0, A20340P0

Our service

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

Used in Process or Applications

High voltage transducers and signal conditioners for the acquisition and conversion of current, voltage, temperature, speed, strain and resistance signals.

Relevant Blog Posts

SE605H conductivity sensor with CondCheck: Integrated sockets for connecting a resistance decade

SE605H Conductivity Sensor with CondCheck

The SE605H conductivity sensor with CondCheck enables USP 645 verification without interrupting the measuring chain.

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

SE655X Digital and SE656X Digital - Digital Conductivity Sensors with Ex Certification

The SE655X digital and SE656X digital conductivity sensors with Memosens protocol are now also available with Ex certification.

New SE656N digital conductivity sensor

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.