Skip to main content Skip to search Skip to main navigation

A20340 Standard-signal Multiplier | 6-Port Isolation

Description

A20340 Standard-signal Multiplier | 6-Port Isolation

Signal multiplier with four calibrated outputs, also for applications with high output loads.

  • Safety in the smallest space
    6-port isolation in 22.5 mm modular housing
  • Signal multiplication
    combined with signal conversion
  • Load increase
    up to 1000 ohms possible for inputs with high input impedances
  • Standards-compliant personal protection
    through protective separation according to EN 61140
  • Precise signal reproduction
    thanks to a short response time of T90 = 1 ms, even dynamic signal changes are accurately reproduced
  • Low-cost solution
    only one compact, low-cost device is required instead of four conventional signal conditioners

The A20340 signal multiplier is an extremely compact product that also provides a cost-effective solution to the problem. In this module, the input, all 4 outputs, and the power supply are safely decoupled from one another (six-port isolation).

In addition to “quadrupling” the analog signal, the A20340 is capable of calibrated signal transmission with signal isolation.

We look forward to hearing from you!
Contact Us

Technical details

Function: Decoupled distribution of standard signals
Input: 0 ... 20 mA, 4 ... 20 mA
Output: 0 ... 20 mA, 4 ... 20 mA
Isolation AC/DC: up to 300 V
Test Voltage: 2.5 kV AC
Power Supply: 24 V DC
Ambient operating temperature: 0 … 55 °C
Dimensions (W x L x H): 6.2 x 93 x 101 mm
Special features: All ports galvanically decoupled (6-port isolation), Signal quadrupler with calibrated inputs and 4 outputs, each driving full loads up to 500 ohms
Product Category: Signal Multiplier

Downloads

Manuals

[16589] User Manual (DE, EN, ZH)
A20340P3
Version 02

Brochures

[14160] Brochure
Product Overview Interface Technology

Data Sheets

[16583] Data Sheet
A20340
Product Description | Specifications | Product Range

Certificates

[11272] EU Declaration of Conformity (DE, EN, FR)
No. EU220125I | 2022-01-25
A20300P0, A20340P0

Our service

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

Used in Process or Applications

High voltage transducers and signal conditioners for the acquisition and conversion of current, voltage, temperature, speed, strain and resistance signals.

Relevant Blog Posts

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Worldwide smallest transducer up to ±2200 V

The P40000 series from Knick enables reliable voltage measurements from ±50 mV to ±3600 V and current measurements from ±100 mA to ±20 kA.

Measuring Photovoltaic Degradation

Photovoltaic (PV) array degradation is an important aspect to consider for system design and installation.

Electrical Measurement Solutions: Control from 480 to 4800 Volts

Voltage and current transducers from Knick bring true control to electrical measurement applications across a wide-range of industries.

Benefits of High Voltage Transducers versus Instrument Transformers

When a need arises to step voltage in a circuit either up or down for purposes of power transmission or distribution, there is no doubt that transformers are essential.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.