2-wire-transmitter for pH and ORP measurement

  • Digital communication: HART
  • Two current outputs
  • Intuitive operation with color-coded user guidance
  • IP 66/67, NEMA 4X protection
  • Automatic sensor identification
  • Sensor diagnostic with wear indication, remaining lifetime, CIP/SIP counter and adaptive calibration timer
  • High-contrast widescreen display with colored backlighting
  • Protective pane made of safety glass
  • One analog input (4 ... 20 mA) e.g. for external pressure compensation
  • Two parameter sets
  • Two digital inputs: 
    • External HOLD activation
    • External switching between parameter set
  • Logbook (200 entries)
Outstanding properties
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
 
Wide Range of Functions
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value. 

We look forward to hearing from you!
Contact Us

Technical details

2- or 4-wire: 2-wire
Channels: 1 channel
Communication (Output, Digital): HART
Display: LC display with colored backlighting
Measurement Parameter: pH/ORP
Sensor Connection: Analog
permanently installed / portable: permanently installed
Current outputs: 2x 4…20 mA
Explosion protection: No
Enclosure: Molded enclosure, PBT/PC, glass-reinforced
Product Line: Stratos, Stratos Pro

Downloads

Manuals

[13316] Changelog Firmware History
[13497] Transmitter Specific HART Command Specification
A211 PH / A411 PH
Device Revision: 2
[13502] Transmitter Specific HART Command Specification
A201 PH ComSpec DevRev03
Device Revision: 3
[13507] Transmitter Specific HART Command Specification
Stratos Evo A402 pH / Stratos Pro A201 pH
Device Revision: 5
[13887] Transmitter Specific HART Command Specification
Stratos Evo A402 pH | DevRev 05
Device Revision: 6
[14536] Transmitter Specific HART Command Specification
Stratos Pro A201 PH
Device Revision: 7
[16503] Transmitter Specific HART Command Specification
Stratos Pro A201 pH
Device Revision: 08
[3940] User Manual
Stratos Pro A201 PH
pH Measurement
Version 05
[9136] Quickstart Guide
Stratos Pro A2... PH
pH Measurement
Version 03

Brochures

[14695] Brochure
Stratos Pro
2-wire analyzers for pH/ORP, conductivity or oxygen

Data Sheets

[16180] Data sheet (EN)
Stratos Pro A201
Product Description | Specifications | Product Range

Certificates

[12917] Quality Control Certificate
Device Settings for Customer-Specific Buffer Solutions
Version 01

Safety guides

[7598] Safety Guide
Stratos Pro / MS / Evo Series
Installation and Use in Hazardous Locations
Version 05

Software

[12198] EDD (PDM)
Stratos Pro A201 pH
Device Revision 02
[12200] EDD (AMS)
Stratos Pro A201 pH
Device Revision 02
[12212] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 03
[13460] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 02
[13468] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 04
[13477] EDD (PDM)
Stratos Pro A201 pH
Device Revision 03
[13482] EDD (PDM)
Stratos Pro A201 pH
Device Revision 04
[13487] EDD (AMS)
Stratos Pro A201 pH
Device Revision 03
[13492] EDD (AMS)
Stratos Pro A201 pH
Device Revision 04
[13872] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 06
[13877] EDD (PDM)
Stratos Pro A201 pH
Device Revision 06
[13882] EDD (AMS)
Stratos Pro A201 pH
Device Revision 06
[14521] EDD (AMS)
Stratos Pro A201 pH
Device Revision 07
[14526] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 07
[14531] EDD (PDM)
Stratos Pro A201 pH
Device Revision 07
[16485] EDD (AMS)
Stratos Pro A201 pH
Device Revision 08 (02)
[16491] EDD (PDM)
Stratos Pro A201 pH
Device Revision 08 (02)
[16497] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 08
[18054] Software
KnUT (Knick Update Tool)

Our service

Used in Process or Applications

In a wide range of industrial sectors, cooling towers are used to dissipate process heat from cooling circuits. Mineral deposits and corrosion reduce their efficiency and lead to premature wear on plant parts.

Related Products

Relevant Blog Posts

SE605H conductivity sensor with CondCheck: Integrated sockets for connecting a resistance decade

SE605H Conductivity Sensor with CondCheck

The SE605H conductivity sensor with CondCheck enables USP 645 verification without interrupting the measuring chain.

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

SE655X Digital and SE656X Digital - Digital Conductivity Sensors with Ex Certification

The SE655X digital and SE656X digital conductivity sensors with Memosens protocol are now also available with Ex certification.

New SE656N digital conductivity sensor

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media