Product added to compare
Product Compare added Product Compare

SE555 pH/ORP Sensor | Memosens | 225 mm | Ex | CIP/SIP capable | Sterilizable | For aggressive media

Description

SE555 pH/ORP Sensor | Memosens | 225 mm | Ex | CIP/SIP capable | Sterilizable | For aggressive media

Steam-sterilizable sensor providing high reliability and precision, digital, with Memosens technology

  • Simultaneous measurement of pH and ORP
  • Gel electrolyte, pressurized and long-term stable
  • Ceramic junction
  • Silver ion trap
  • Integrated temperature detector
  • Omega glass with high impedance for high-temperature applications, very low alkali error
  • CIP/SIP capable, safe sterilization with temperature monitoring
  • Perfect galvanic isolation thanks to Memosens technology
  • No influence of humidity in the connector
  • Precalibration in the lab
  • Digital data transfer
  • Integrated sensor diagnostics

The digital pH/ORP sensor SE555X/1-AMSN has a special pH glass with high impedance for high-temperature applications and low alkali error as well as a platinum disk as ORP measuring element.

The sensor is CIP and SIP capable. The silver ion trap prevents contamination and blocking of the junction by silver sulfide in sulfide-containing media. The reference electrolyte is biocompatible. This makes the sensor predestined for applications in food and biotechnology, but it is also suitable for continuous and simultaneous measurement of pH and ORP in process chemistry or wastewater.

In addition, the Memosens technology offers all known advantages in terms of handling and sensor diagnostics.

Applications
Fermentation, food and beverages, aggressive media, extreme pH values, waste water

We look forward to hearing from you!
Contact Us

Technical details

Measurement Parameter: pH/ORP
Connector: Memosens
Explosion protection: Ex
Length: 225 mm
Measuring Range: 0 … 14 pH, ± 1500 mV
Temperature: 0 … 135 °C
Pressure, relative: -1 … 6 bar
Temperature Detector: NTC 30 kΩ
Junction: Ceramic (1x)
Reference System: Ag/AgCl with silver ion trap
Sensor Material: Omega glass, high impedance, low alkali error, Platinum
Electrolyte: Prepressurized gel electrolyte

Downloads

Manuals

[16286] User Manual (DE, EN, KO)
Memosens Cable CA/MS
Version 09
[12389] User Manual (DE, EN)
SE555X/*-AMSN | -NMSN | -NVPN | -NS8N
Version 04
[14165] User Manual (DE, EN)
ZU 1054 Sensor Protection (Sensorschutz)

Brochures

[13395] Brochure
Sensors - For measuring pH/ORP, conductivity or oxygen. Digital or analog.

Data Sheets

[16951] Data sheet
SE555X/*-AMSN Memosens pH/ORP Sensor
Product Description | Specifications | Product Range

Certificates

[11064] EU Declaration of Conformity
No. EU210427A | 2021-04-27
Memosens Sensors | Types SE 5..X..-.MS., SE604X-MS**, SE605….., SE6**X**MS, SE7**…
[14685] Certificate of Conformity (FM)
No. FM17US0208X | 2019-05-27 | USA
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[12113] Confirmation (DE, EN)
Kein tierischer Ursprung / No components of animal origin
Series SE 555X/*-*MS*, SE555X/*-*VP*, SE 555X/*-*S8
[17427] Type Examination Certificate for Ex-Equipment (Japan)
No. CML 20JPN2077X | from 10-07-2020 to 09-07-2023
MEMOSENS CA/MS-***X**-JP
[14690] Certificate of Conformity (FM)
No. FM17CA0105X | 2019-05-27 | Canada
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[16292] Korean safety certificate Kosha (KO)
No. 2020-KA4BO-0368X
Measuring Cable CA/MS
[12826] EU-Type Examination Certificate (DEKRA)
Nr. BVS 16 ATEX E 037 X | 2024-02-20
Memosens-Ex-Sensors
[12831] IECEx Certificate of Conformity
Memosens Ex Sensors | Details see Document
Document No. IECEx BVS 16.0030X, issue No. 2 | 2024-02-23
Marking: Ex ia IIC T3/T4/T6 Ga
[14155] Declaration of Compliance 2.1 (DE, EN)
according to EN 10204 | gemäß EN 10204

Safety guides

[11045] Material Safety Data Sheet
CaliMat buffer solution pH 7,00
[11048] Material Safety Data Sheet
CaliMat buffer solution pH 4,00
[11046] Material Safety Data Sheet
CaliMat buffer solution pH 9,00
[11049] Material Safety Data Sheet
CaliMat buffer solution pH 2,00
[11044] Material Safety Data Sheet
CaliMat buffer solution pH 12,00

Control Drawings

[14185] Control Drawing
Inductive Sensor-Cable Connection System Memosens
Zeichnungsnummer 214.410-240

Our service

Used in Process or Applications

Measurement of pH value, redox potential, and conductivity in cooling water, which has to be continuously treated with acid and biocides.
The taste and quality of beer are highly dependent on the quality of the water used for brewing it. It is determined by pH and conductivity measurements.
Sugar production places extreme requirements on pH sensors. As early as the beet washing phase, it is important to monitor the pH value since the lime is metered on the basis of the pH measurement.
In a wide range of industrial sectors, cooling towers are used to dissipate process heat from cooling circuits. Mineral deposits and corrosion reduce their efficiency and lead to premature wear on plant parts.
High quality requirements are placed on raw milk, and online monitoring of truck unloading procedure at the dairy prevents inferior quality (sour milk) from spoiling the entire stock of the storage tank.

Related Products

Relevant Blog Posts