Digital, sterilizable pH sensor providing high reliability and precision.

  • Also available as version with-out paint-wetting impairment substances (PWIS-free)
  • Gel electrolyte, pressurized
  • Ceramic junction
  • Silver ion trap
  • Integrated temperature detector
  • pH glass with high impedance for high-temperature applications, low alkali error
  • CIP/SIP-capable, safe sterilization with temperature monitoring
  • Perfect galvanic isolation thanks to Memosens technology
  • No influence of humidity in the connector
  • Precalibration in the lab
  • Digital data transfer
  • Integrated sensor diagnostics

The SE555 digital pH sensor comes with a special pH glass with high impedance for high-temperature applications and a low alkali error. The sensor is CIP- and SIP-capable. The silver ion trap prevents silver sulfide precipitation and junction fouling in media containing sulfides.

This makes the sensor ideal for routine applications in food processing and biotechnology. Additionally the Memosens technology offers all well known advantages concerning operation and sensor diagnostics.

Applications
Fermentation, food and beverages, aggressive media, extreme pH values

We look forward to hearing from you!
Contact Us

Technical details

Measurement Parameter: pH
Connector: Memosens | PWIS-free
Explosion protection: Ex
Length: 120 mm
Process Connection: PG 13.5
Measuring Range: 0 … 14 pH
Temperature: 0 … 135 °C
Pressure, relative: -1 … 6 bar
Temperature Detector: NTC 30 kΩ
Junction: Ceramic (1x)
Reference System: Ag/AgCl with silver ion trap
pH Glass: Omega glass, high impedance, low alkali error
Electrolyte: Prepressurized gel electrolyte

Downloads

Manuals

[16286] User Manual (DE, EN, KO)
Memosens Cable CA/MS
Version 09
[12389] User Manual (DE, EN)
SE555X/*-AMSN | -NMSN | -NVPN | -NS8N
Version 04
[14165] User Manual (DE, EN)
ZU 1054 Sensor Protection (Sensorschutz)

Brochures

[13395] Brochure
Sensors - For measuring pH/ORP, conductivity or oxygen. Digital or analog.

Data Sheets

[2502] Data sheet
SE555X/*-NMSN(-LABS) Memosens pH Sensor
Product Description | Specifications | Product Range

Certificates

[11064] EU Declaration of Conformity
No. EU210427A | 2021-04-27
Memosens Sensors | Types SE 5..X..-.MS., SE604X-MS**, SE605….., SE6**X**MS, SE7**…
[14685] Certificate of Conformity (FM)
No. FM17US0208X | 2019-05-27 | USA
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[13263] Declaration of Conformity
Cytotoxicity of the Test Material "Electrolyte gel Rheolid" | 2010-08-02
SE 555X/.-NMSN
[17427] Type Examination Certificate for Ex-Equipment (Japan)
No. CML 20JPN2077X | from 10-07-2020 to 09-07-2023
MEMOSENS CA/MS-***X**-JP
[14690] Certificate of Conformity (FM)
No. FM17CA0105X | 2019-05-27 | Canada
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[12113] Confirmation (DE, EN)
Kein tierischer Ursprung / No components of animal origin
Series SE 555X/*-*MS*, SE555X/*-*VP*, SE 555X/*-*S8
[16292] Korean safety certificate Kosha (KO)
No. 2020-KA4BO-0368X
Measuring Cable CA/MS
[16262] Korean safety certificate Kosha (KO)
No. 2020-KA4BO-0355X
SE55*Xl*-NMSN, SE605H-XMS****
[12826] EU-Type Examination Certificate (DEKRA)
Nr. BVS 16 ATEX E 037 X | 2024-02-20
Memosens-Ex-Sensors
[12831] IECEx Certificate of Conformity
Memosens Ex Sensors | Details see Document
Document No. IECEx BVS 16.0030X, issue No. 2 | 2024-02-23
Marking: Ex ia IIC T3/T4/T6 Ga
[14155] Declaration of Compliance 2.1 (DE, EN)
according to EN 10204 | gemäß EN 10204

Safety guides

[11045] Material Safety Data Sheet
CaliMat buffer solution pH 7,00
[11048] Material Safety Data Sheet
CaliMat buffer solution pH 4,00
[11046] Material Safety Data Sheet
CaliMat buffer solution pH 9,00
[11049] Material Safety Data Sheet
CaliMat buffer solution pH 2,00
[11044] Material Safety Data Sheet
CaliMat buffer solution pH 12,00

Control Drawings

[14185] Control Drawing
Inductive Sensor-Cable Connection System Memosens
Zeichnungsnummer 214.410-240

Our service

Used in Process or Applications

Measurement of pH value, redox potential, and conductivity in cooling water, which has to be continuously treated with acid and biocides.
The taste and quality of beer are highly dependent on the quality of the water used for brewing it. It is determined by pH and conductivity measurements.
Sugar production places extreme requirements on pH sensors. As early as the beet washing phase, it is important to monitor the pH value since the lime is metered on the basis of the pH measurement.
In a wide range of industrial sectors, cooling towers are used to dissipate process heat from cooling circuits. Mineral deposits and corrosion reduce their efficiency and lead to premature wear on plant parts.
High quality requirements are placed on raw milk, and online monitoring of truck unloading procedure at the dairy prevents inferior quality (sour milk) from spoiling the entire stock of the storage tank.

Related Products

Relevant Blog Posts

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

Successful joint project : Knick developed the special Ceramat WA 155 retractable fitting for optical probes from SOPAT

In cooperation with SOPAT, Knick developed a special Ceramat fitting for optical probes for automatic cleaning in fouling processes.

High-quality immersion fitting for mobile applications

ARD 170 enables measurements even in deep water

Modular immersion fitting as an electrically conductive variant

Knick is expanding its portfolio of fittings for liquid analysis with additional electrically conductive (EL) variants.

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.