P42000 TRMS AC/DC High Voltage Transducer / Transmitter
                                            
                            Product number:
                        
                    
                                            
                        
                            P42000TRMS
                        
                                    
                    
                
                                                                                                Description
                P42000 TRMS AC/DC High Voltage Transducer / Transmitter
            
                    
                                                        AC/DC high voltage transducers for true rms measurement Input voltages up to Vin = 3600 V AC
- Universal usability:
- AC input 60 mV~ up to 3600 V~ as well as 100 mA~ up to 5 A~
 - DC output 0 (4) … 20 mA, 0 … 10 V
 
 - TransShield technology
enables extremely compact modular housings - Working voltages up to 3600 V AC/DC
 - Protection against electric shock
with protective separation up to 1800 V AC/DC according to EN 61140 - Test voltages up to 15 kV AC
 - Excellent transmission properties:
- Gain error Crest factor ≤ 3 < 0.5 %
 - Gain error Crest factor 3 … 5 < 1 %
 - Response time T90 < 150 ms
 
 - Virtually no influence from common-mode voltages:
CMRR approx. 150 dB - Tremendous flexibility provided by
- Calibrated switching of up to 16 input/output ranges
 - up to 16 customer-specific measuring ranges
 - 20 V to 253 V AC/DC broad-range power supply
 
 - Reliable function even with unstable supply
 - No damage
in the case of erroneous power connection - Switchable models
minimize required device variants and save stockkeeping costs - Robust
thanks to vacuum encapsulation - Mechanically stable
for operation on ships, rail vehicles and land crafts - 5-year warranty
 
The P42000 TRMS isolation amplifiers have been specially conceived for measuring high voltages up to 3600 V AC/DC. They reliably isolate high potentials at the input circuit. Thanks to the true rms conversion in the transducer, even distorted input signals are captured correctly and output as so-called true rms values.
The isolating distances are designed to withstand permanent voltages up to 3600 V AC/DC and fast transients up to 20 kV.
            
                We look forward to hearing from you!
                Contact Us
            
        
| Function: | True-RMS of AC voltages | 
|---|---|
| Input: | 0 ... 10 V AC, 0 ... 3600 V AC | 
| Output: | 0 ... (±)10 V, 0 ... (±)20 mA, 4 ... 20 mA, Peak or TRMS values | 
| Isolation AC/DC: | 2,200 V, up to 3,600 V | 
| Test Voltage: | 10/15 kV AC | 
| Power Supply: | 22 ... 230 V AC/DC | 
| Cutoff Frequency: | Cutoff frequency 5 kHz; lower cutoff frequencies on request | 
| Ambient operating temperature: | –10 ... 70 °C | 
| Dimensions (W x L x H): | 45 x 90 x 118 mm (D2), 67.5 x 90 x 118 mm (D3) | 
| Special features: | Exceptionally high MTBF of 2165 years (Mean Time Between Failures), based on field data, High isolation in a compact housing, Switchable (16 input/output signal combinations) or customized versions | 
| Product Category: | High Voltage Transducer |