Wind Turbine Measurements

The development of wind energy production is characterized by ever larger turbines up to multi-megawatt size, complex terrain (e.g., offshore), and the resulting higher investment costs and increasing productivity demands.

For monitoring the efficiency of wind turbines, various measurement sensors are used whose unipolar and bipolar signals have to be combined and converted for further processing. The collected data can be evaluated in terms of the wind conditions, energy output, noise emissions, and shadows cast.

Current and voltage signals must be transmitted over large distances to the data capture system in a manner that is as free from interference as possible. Data capture systems and sensors are often subjected to extreme environmental conditions.

Measuring wind turbines

Factors that could have a negative effect on the profitability of wind turbines must be continuously monitored. In order to guarantee the optimal output, modern wind turbines contain a range of sensors whose measuring signals must be acquired, converted, and queried – in many cases over long distances.

Here, the P27000 universal isolated signal conditioner guarantees protection against overvoltage and measuring signal distortion from potential differences. Its advantage is that up to 480 input and output ranges are calibrated and switchable with DIP switches. Their switching is controlled digitally and does not require any complicated readjustment.

With a gain error of less than 0.08 % of measured value and a temperature coefficient of less than 0.005 %/K of input value, P27000 provides constantly high transmission quality that exceeds all requirements placed on industrial measuring technology. Smart circuit design keeps the power dissipation of the device low, reducing heat build-up such that the enclosure remains cold. In turn, this extends the service life of the electronic components.

With their 3-port isolation between input, output and auxiliary power, the devices in a narrow modular housing with a width of only 12.5 mm have such a compact design that up to 80 signal conditioners can fit on a one-meter DIN rail.

Return on investment

  • Lower service costs with longer intervals thanks to a longer service life
  • High flexibility with only one product type that supports different measurement methods and can be operate with almost any supply voltage
  • Reliable protection of the measured data tracking system and measuring channels among each other
  • Accuracy that exceeds industrial requirements, even under extreme conditions
  • Low power dissipation, thanks to smart circuit design

Matching products

Associated industries and applications

The degradation of photovoltaic power stations (PV) is an important aspect that must be taken into consideration when designing and installing the system. Over time, factors like the weather and UV irradiation contribute to the power loss of the solar cells. With a better understanding of the degradation effect, protective measures and technological improvements can possibly be considered in order to improve performance.
Knick transducers and signal conditioners have been used in a range of applications in the energy industry for many decades

Latest blog post

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

InnoTrans 2022 - three products as world firsts for rolling stock and DC traction power supply applications

At InnoTrans 2022 Knick presented 3 products as world firsts for rolling stock and DC traction power supply applications.

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

P52000VPD voltage presence detector reliably detects voltages up to 4200 V DC

The new P52000VPD voltage presence detector reliably monitors areas with high voltages and sends a signal to the downstream plant control system when a specified threshold value is reached.

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

Quadruple Standard Signals in Just One Signal Conditioner

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Pulse frequency conditioner for speed sensors

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

Worldwide smallest transducer up to ±2200 V

The P40000 series from Knick enables reliable voltage measurements from ±50 mV to ±3600 V and current measurements from ±100 mA to ±20 kA.

Importance of broad-range power supplies for DC electrical measurement

Many DC electrical measurement products manufactured by Knick contain universal, also known as broad-range, power supplies.

Measuring Photovoltaic Degradation

Photovoltaic (PV) array degradation is an important aspect to consider for system design and installation.

Electrical Measurement Solutions: Control from 480 to 4800 Volts

Voltage and current transducers from Knick bring true control to electrical measurement applications across a wide-range of industries.

Benefits of High Voltage Transducers versus Instrument Transformers

When a need arises to step voltage in a circuit either up or down for purposes of power transmission or distribution, there is no doubt that transformers are essential.

Shunt Resistor versus Hall Effect Technology

There are many systems where measurement of large DC currents are needed for performance and safety.

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together