SE680 Digital Toroidal Conductivity Sensor | Clamp 2" | Ex | FDA-approved PEEK | Measuring range 0 … 2000 mS/cm

High-precision sensor made of FDA-approved PEEK with an extremely large measuring range. Steam-sterilizable.

High-precision sensor made of FDA-approved PEEK with an extremely large measuring range. Steam-sterilizable.

  • Compact design
  • Competitively priced
  • Large measuring range
  • Quick-reacting temperature detector
  • Digital data transfer
  • Completely closed surface
  • Virgin PEEK, FDA type
  • Varivent with EHEDG

The joint- and gap-free, sealless design and stain-resistant surface made of Virgin PEEK make the SE680 a heavy-duty sensor. The inductive technology is not influenced by polarization and does not have any sensor surfaces subject to corrosion.

Applications
Fresh water technology, dairy products, breweries, soft drink manufacturing, electroplating, air-conditioning, CIP monitoring in the beverage industry, pharmaceutical applications, cooling tower monitoring, on-site wastewater treatment plants, monitoring concentrations of salt solutions, alkalis and acids, washers, and rinsing processes

  • Compact design
  • Competitively priced
  • Large measuring range
  • Quick-reacting temperature detector
  • Digital data transfer
  • Completely closed surface
  • Virgin PEEK, FDA type
  • Varivent with EHEDG

High-Precision Conductivity Measurement at Extreme Temperature Differences

Pharmaceutical manufacturer, EVER Pharma Jena uses the extremely robust conductivity sensors SE605(H) and SE680 with Memosens technology from Knick.

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

Error: ± 1 % d. m. + 0,002 mS/cm, ± 0,02 %/K
Facteur de cellule: c ≈ 5,0/cm
Matériaux en contact avec le milieu: Virgin PEEK, type FDA
Matériaux sans contact avec le milieu: PP-ESD
Paramètres de mesure: conductivité (induktive)
Principe de mesure: Inductif
Raccordement process: Clamp 2"
Raccordement électrique: Connecteur M12 – 4 pôles Longueur de câble max. 100 m
Sonde de température: Pt1000
Stérilisation: ≤ 5 bar / ≤ 150 °C / ≤ 60 min
Temps de réponse: t90 < 30s
Transmission du signal: numérique
Plage de mesure: 0 … 2 000 mS/cm
Protection contre les explosions: Ex zone 0, Oui
Relative process pressure: -0,1 ... 10 bar (cf. diagramme pression-température)

Téléchargements

Manuals

[12413] Manuel utilisateur
SE680 (N/X)
Version 08

Brochures

[13395] Brochure
Sondes - Pour la mesure du pH/redox, de la conductivité et de l’oxygène. Numérique et analogique.

Fiches techniques

[2993 Fiche technique
Sonde de conductivité inductive SE680
Description du produit | Caractéristiques techniques | Gamme de produits

Certificats

[13847] Manufacurer's Declaration | Herstellererklärung
USP-Klassifizierung und der FDA-Konformität der Kunststoffe der Sensoren SE680N/* und SE680X/*
USP Classification and FDA Conformity of the Plastic Material in SE680N/* und SE680X/*
2025-03-18
[13137] EU Type-Examination Certificate / EU-Baumusterprüfbescheinigung
No. TÜV 15 ATEX 154534 X | 2021-06-24
SE 680X-****U0** Conductivity Sensor
[13132] EU Declaration of Conformity (DE, EN, FR)
No. EU210706C | 2021-07-06
Digital Toroidal Conductivity Sensor Series SE680X-...U0..
[14685] Certificate of Conformity (FM)
No. FM17US0208X | 2019-05-27 | USA
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[14690] Certificate of Conformity (FM)
No. FM17CA0105X | 2019-05-27 | Canada
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[16268] Korean Safety Certificate
SE680X-**N4UOOM
Ex ia IIC T3/T4/T6
Kosha 2020-KA4BO-0354X

Notre service

Utilisé dans les processus ou les applications

Mesure fiable de la conductivité dans les process CIP/SIP avec des différences de température extrêmes
Le goût et la qualité de la bière dépendent en grande partie de la qualité de l’eau. Celle-ci est déterminée par des mesures du pH et de la conductivité.

Produits apparentés

Ignorer la galerie de produits

Articles de blog pertinents

Nouveau transmetteur Stratos Multi E461N avec Profinet

L'interface Profinet du nouveau transmetteur multiparamètres Stratos Multi E461N permet une communication continue des paramètres de process et une maintenance prédictive, du niveau du terrain jusqu'aux systèmes de contrôle des process usuels.

Programmation hors ligne confortable des transmetteurs sur PC: ProgaLog 4000

Avec ProgaLog 4000, vous pouvez facilement paramétrer hors ligne tous les transmetteurs à configuration modulaire Stratos Multi et Protos II 4400, enregistrer les réglages, les dupliquer pour d'autres transmetteurs et les documenter pour des audits.

Stratos Multi E401X- Transmetteur multiparamètres pour zones Ex

Le nouveau Stratos Multi peut désormais être utilisé dans les zones Ex.

Optimisation des process avec Stratos Multi E471 par EtherNet/IP

EtherNet/IP communication protocol allows the transmitter to be easily integrated into Industrial Ethernet networks as PCS.

New multiparameter transmitter Stratos Multi

Knick is launching the the next generation in its Stratos analyzer product line.