Universal and precise conductivity sensor with high chemical resistance. Digital with Memosens protocol.

  • Process-wetted material: PEEK
  • Sturdy design
  • Resistant to contamination and fouling
  • Range of six decades
  • Steam sterilizable and CIP capable
  • Inductive measuring principle, full galvanic isolation of sensor coils from process medium 
  • Digital with Memosens protocol
  • Also for hazardous areas

The SE655N digital toroidal conductivity sensor is a sturdy and corrosion-resistant sensor that, thanks to its high chemical resistance, is particularly suitable for applications in the chemical industry.

A combination of a large sensor opening and dirt-repellent material prevents blockages and deposits in media with a high pollution degree. The inductive measuring principle enables full galvanic isolation of the measurement from the medium.

The sensor is an all-rounder, suitable for a multitude of applications with a range covering six decades. Equipped with Memosens protocol as a digital version, it offers considerable process and data security, and ensures reliable data recording. Also for hazardous areas (SE655X-GEFTT0AM).

Applications
Concentration measurement of acids and bases, online quality monitoring of chemical products in tanks and pipes, phase separation of product mixtures, paper manufacturing (high fiber concentration), heavily soiled media and wastewater, fouling and oil-contaminated media, brine, regeneration of ion exchangers.

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

Différence de mesure: ± (0,005 mS/cm + 0,5 % de la valeur mesurée) | (-20 ... +100 °C), ± (0,010 mS/cm + 0,5 % de la valeur mesurée) | (> 100 °C)
Facteur de cellule: 1,98/cm (≥ 30 mm distance au mur)
Matériau: Célula: PEEK; gaxeta: FKM (Viton)
Paramètres de mesure: conductivité (induktive)
Principe de mesure: Inductif
Protection: IP 68 (sonde montée avec joint d'origine / EN 60529)
Raccordement process: G 3/4“ (écrou surplat 36 et joint FKM (Viton) inclus dans le contenu)
Résolution: 0,002 µS/cm
Sonde de température: Pt1000 (classe A selon IEC 60751)
Temps de réponse température t90: env. 7 min
Température ambiante: –20 ... 60 °C
Température de stockage: –20 ... 80 °C
Transmission du signal: Memosens-Protokoll
Plage de mesure: 0 … 2 000 mS/cm
Protection contre les explosions: Oui
Relative process pressure: 0 ... 20 bar (cf. diagramme pression-température)
Fixed cables with ferrules: 7 m

Téléchargements

Manuals

[13989] User Manual
SE655(N/X-*) / SE656(N/X-*)
Digital Toroidal Conductivity Sensor

Brochures

[13395] Brochure
Sondes - Pour la mesure du pH/redox, de la conductivité et de l’oxygène. Numérique et analogique.

Fiches techniques

[16521] Fiche technique
Sonde de conductivité inductive SE655(N/X)
Description du produit | Caractéristiques techniques | Gamme de produits

Certificats

[11819] EU-Type Examination Certificate
No. DMT 01 ATEX E 088X | Supplement 3 | 2019-09-21
Electrodeless Sensor Model type SE 65*X-********
[17436] EU Declaration of Conformity
No. EU210607A | 2021-06-07
SE655X-GE**TO*M / SE656X-GE**WO*M
[17553] Korean Safety Certificate
Ex ia IIC T4/T6 Ga / 23-KA4BO-0105X
SE65*X-GE***0*M
2023-02-21
[16734] EU Type-Examination Certificate / EU-Baumusterprüfbescheinigung
BVS 20 ATEX E 113 X | 2021-01-04
Types SE655X-GE**TO*M & SE656X-GE**WO*M
[16728] IECEx Certificate of Conformity
No.: IECEx BVS 20.0087X
Digital inductive conductivity sensor type SE655X-GE**T0*M and SE656X-GE**W0*M

Notre service

Utilisé dans les processus ou les applications

Le goût et la qualité de la bière dépendent en grande partie de la qualité de l’eau. Celle-ci est déterminée par des mesures du pH et de la conductivité.
Les stations d’épuration biologique des eaux usées rejettent des boues d’épuration toxiques, qui doivent être traitées pour récupérer le phosphore.
Dans le cadre de la production de cellulose, de nombreux postes de mesure sont placés dans des environnements où le temps de présence du personnel technique doit être limité au strict minimum.

Produits apparentés

Ignorer la galerie de produits

Articles de blog pertinents

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.