Skip to main content Skip to search Skip to main navigation

P43000 High Voltage Transducer / Transmitter | Calibrated and Switchable

Description

P43000 High Voltage Transducer / Transmitter | Calibrated and Switchable

Universal high voltage transducers. Input currents up to Iin = 5 A.

  • Universal high voltage transducers
    for converting input currents up to 5 A to impressed ±20 mA, ±10 V, or 4 … 20 mA output signals
  • New TransShield technology
    enables extremely compact modular housings
  • Working voltages
    up to 3600 V AC/DC
  • Protection against electric shock
    with protective separation up to 1800 V AC/DC according to EN 61140
  • Test voltages up to 15 kV AC
  • Excellent transmission properties:
    • Gain error < 0.3 %
    • Cutoff frequency 5 kHz (low-pass filter / lower cutoff frequency on request)
    • Rise time T90 approx. 110 µs
  • Tremendous flexibility provided by
    • Calibrated switching of up to 16 input/output ranges (working voltage up to 2200 V)
    • Up to 16 customer-specific measuring ranges
    • 20 V to 253 V AC/DC broad-range power supply
  • Reliable function
    even with unstable power supply
  • No damage
    in the case of erroneous power connection
  • Switchable models
    minimize required device variants and save stockkeeping costs
  • Robust
    thanks to vacuum encapsulation
  • Mechanically stable
    for operation on ships, rail vehicles and land crafts
  • 5-year warranty

The P43000 isolation amplifiers have been conceived for direct measurement of currents up to 5 A (DC). They reliably isolate high potentials at the input circuit.

The isolating distances are designed to withstand permanent voltages up to 3600 V AC/DC and fast transients up to 20  kV. Protection against electric shock is achieved through protective separation according to EN 61140 between input and output and power supply.

 

We look forward to hearing from you!
Contact Us

Technical details

Function: Current measurement on high potential
Input: 0 ... (±)0.1 A upt to 0 ... (±)5 A
Output: 0 ... (±)10 V, 0 ... (±)20 mA, 4 ... 20 mA, Peak or TRMS values
Isolation AC/DC: up to 3,600 V
Test Voltage: 10/15 kV AC
Power Supply: 22 ... 230 V AC/DC
Cutoff Frequency: Cutoff frequency 5 kHz; lower cutoff frequencies on request
Ambient operating temperature: –10 ... 70 °C, –40 ... 75/85 °C
Dimensions (W x L x H): 45 x 90 x 118 mm (D2)
Special features: Exceptionally high MTBF of 2165 years (Mean Time Between Failures), based on field data, Switchable or customized versions
Product Category: High Voltage Transducer

Downloads

Manuals

[17381] User Manual
P43000 - High Voltage Transducer
Version 06

Brochures

[14160] Brochure
Product Overview Interface Technology

Data Sheets

[1513] Data Sheet
VariTrans P 41000, P 42000 (inkl. D2), P 43000
Product Description | Specifications | Product Range

Certificates

[11463] EU Declaration of Conformity (DE, EN, FR)
Series VariTrans P4x000 (D*-nnnn/D*AG-nnnn/D*TRMS-nnnn)
No. EU221209A | 2023-11-29
[12071] Certificate of Compliance (UL)
P41000, P42000, P43000, P44200, P51000, P52000
MOTOR CONTROLLER ACCESSORIES OVER 1500 VOLTS
No. UL-US-L356768-11-22503102-1 | 202406-28
[14140] Quality Report (MTBF)
Document No. TX180416A
Failure Rate of Series P40000

Software

[11876] Knick Produktmakros (.pdf)
ePLAN Electric P8
[12154] Software (.zip)
ePLAN P8 Produktmakros

Our service

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

Used in Process or Applications

High voltage transducers and signal conditioners for the acquisition and conversion of current, voltage, temperature, speed, strain and resistance signals.

Relevant Blog Posts

SE605H conductivity sensor with CondCheck: Integrated sockets for connecting a resistance decade

SE605H Conductivity Sensor with CondCheck

The SE605H conductivity sensor with CondCheck enables USP 645 verification without interrupting the measuring chain.

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

SE655X Digital and SE656X Digital - Digital Conductivity Sensors with Ex Certification

The SE655X digital and SE656X digital conductivity sensors with Memosens protocol are now also available with Ex certification.

New SE656N digital conductivity sensor

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.