Skip to main content Skip to search Skip to main navigation

Stratos Pro A221X Multiparameter Transmitter | Memosens/Analog Sensors | Ex Zone 0/1 | Profibus

Description

Stratos Pro A221X Multiparameter Transmitter | Memosens/Analog Sensors | Ex Zone 0/1 | Profibus

2-wire analyzer (PROFIBUS DP/PA)

  • Digital communication: PROFIBUS-PA
  • Intuitive operation with color-coded user guidance
  • IP 66/67, NEMA 4X protection
  • Automatic sensor identification
  • Sensor diagnostic with wear indication, remaining lifetime, CIP/SIP counter and adaptive calibration timer
  • High-contrast widescreen display with colored backlighting
  • Protective pane made of safety glass
  • One analog input (4 ... 20 mA) e.g. for external pressure compensation
  • Two parameter sets
  • Two digital inputs: 
    • External HOLD activation
    • External switching between parameter set
  • Logbook (200 entries)
Outstanding properties
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
 
Wide Range of Functions
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value. 
 
Zone 1 Explosion Protection
Stratos Pro is designed for operation in Zone 1 / Class 1 Division 1 hazardous areas (with the sensor in Zone 0). Operation in hazardous areas from –20 °C to +65 °C is possible. The devices are designed for gas and dust explosion protection (G/D) and can naturally also be used outdoors (type 4 enclosure, UV resistant).

We look forward to hearing from you!
Contact Us

Technical details

2- or 4-wire: 2-wire
Channels: 1 channel
Communication (Output, Digital): PROFIBUS
Display: LC display with colored backlighting
Measurement Parameter: pH, Multiparameter, pH/ORP, ORP , Oxygen, Conductivity
Sensor Connection: Memosens | Analog
permanently installed / portable: permanently installed
Current outputs: no mA output
Explosion protection: Yes, hazardous area Zone 1
Enclosure: Molded enclosure, PBT/PC, glass-reinforced
Product Line: Stratos, Stratos Pro

Downloads

Manuals

[17041] ChangeLog Firmware History
A221, A231, A451
1/24/2022
[12606] User Manual
PROFIBUS DP/PA
Stratos Evo A451N | Stratos Pro A221 (N/X)
Version 02

Brochures

[14695] Brochure
Stratos Pro
2-wire analyzers for pH/ORP, conductivity or oxygen

Data Sheets

[16180] Data sheet (EN)
Stratos Pro A201
Product Description | Specifications | Product Range

Certificates

[12917] Quality Control Certificate
Device Settings for Customer-Specific Buffer Solutions
Version 01
[16316] Certitficate of Conformity (China - Ex NEPSI)
Cert No. GYJ20.1052X | 2020-06-10
Stratos Pro A20..X / Multi E401X
[17027] EU Type-Examination Certificate
No. KEMA 08ATEX0100 | 2024-03-07
Issue No. 10
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A221X… and A231X… | Stratos Multi Type E401X
[18023] Korean Safety Certificate
No. 23-KA4BO-0099
2023-02-17
[17021] IECEx Certificate of Conformity
No. IECEX KEM 08.0020
Issue No. 9 | 2024-03-07
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A201B…, A221X…, A231X | Stratos Multi Type E401X
[8040] Certificate of Conformity (FM-Canada)
No. FM21CA0052 (Canada) | 2021-11-01
Stratos Pro Types A201X…, A211X…, A201B…, A221X… and A231X… | Stratos Multi Type E401X
[12922] EU Declaration of Conformity (DE, EN, FR)
No. EU210721A | 2022-07-21
Stratos Pro PA A221X, Stratos Pro FF A231X

Safety guides

[7598] Safety Guide
Stratos Pro / MS / Evo Series
Installation and Use in Hazardous Locations
Version 05

Control Drawings

[16539] Control Drawing
Stratos Pro Type A22.X... or A23.X…
Zeichnungsnummer 212.002-100 page 7 rev.2
ATEX, IECEx

Software

[18054] Software
KnUT (Knick Update Tool)
[17577] SOFTWARE
FDI
Stratos Profibus PA A221 Multi
Device Revision 01
[13601] DTM (Pactware)
Stratos Profibus PA A221 Multi
Device Revision 01
[13606] EDD (PDM)
Stratos Profibus PA A221 Multi
Device Revision 01

Our service

Used in Process or Applications

In a wide range of industrial sectors, cooling towers are used to dissipate process heat from cooling circuits. Mineral deposits and corrosion reduce their efficiency and lead to premature wear on plant parts.

Related Products

Skip product gallery

Relevant Blog Posts

SE605H conductivity sensor with CondCheck: Integrated sockets for connecting a resistance decade

SE605H Conductivity Sensor with CondCheck

The SE605H conductivity sensor with CondCheck enables USP 645 verification without interrupting the measuring chain.
Knick’s large, international team at its ACHEMA 2024 trade fair booth.

ACHEMA 2024 - Review and Impressions

A brief cinematic retrospective of our trade fair booth, Knick’s international team, and a successful booth party.

Uniclean 700 Series - Modular control system for automated sensor cleaning

With the Uniclean 700 series, Knick is introducing a modular control system, that can be installed very quickly and cost-effectively as a flexible entry-level solution for automated sensor cleaning.

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.