Uniclean 900 Electro-pneumatic controller | For automatic cleaning | Ex | Corrosion-proof coating

Description

Uniclean 900 Electro-pneumatic controller | For automatic cleaning | Ex | Corrosion-proof coating

The electro-pneumatic controller for fully automated pH measurement and cleaning

  • operation in hazardous locations Zone 1 (all system components)
  • corrosion-proof (powder-coated steel)
  • consistent enclosure concept for all devices
  • modular design, adaptable to virtually every measuring task
  • easy assembly and retrofitting
  • low maintenance effort due to innovative pump technology and extremely low consumption of media
  • time-controlled cleaning
  • cleaning with water and additional cleaning solution
  • reduced maintenance effort due to automatic cleaning
  • no disruption of production for cleaning the sensor
  • longer sensor life due to short-time measurement and regular cleaning
  • immediate readiness for measurement after production interruption since sensor is safely stored in liquid
  • safety ensured by monitoring of the compressed air and water supply, the probe position and the cleaning solution level

In combination with the Protos process analysis system and a SensoGate or Ceramat sensor lock-gate, Uniclean provides the ideal functionality of a complete system for automatic process control of a pH measurement.

Maximum availability of the point of measurement: Cleaning without disrupting the process, even when measuring directly in the pressure vessel.

Since the sensor is not removed for cleaning, the process can continue uninterrupted. This allows problem-free measurements in a pressure tank or in the main pipe. Elaborate and lockable bypasses are eliminated and accuracy increases.

Low maintenance
Fully automatic sensor cleaning with water or special cleaning solution in user-defined intervals without interrupting the process. The cleaning solution is automatically pumped into the cleaning chamber. Only the containers need to be refilled.

Cost-effective
Low-wear and low-maintenance pumps with extremely low consumption of cleaning agent.

Long sensor life also in critical processes
When measuring in aggressive media or at high process temperatures, the sensor rests in the cleaning chamber and is only briefly moved into the process for measurement. The cleaning chamber may be filled with water. This method increases the sensor life significantly.

Safe and easy measurement even in strongly polluted media
Sensor cleaning and rinsing is performed at user-defined intervals. Cleaning solution and water are automatically pumped into the rinsing chamber. Dismantling and manual cleaning of the sensor are omitted.

Modern fieldbus integration
The interfaces to PROFIBUS PA or Foundation Fieldbus allow the Uniclean system to be integrated directly in a fieldbus network. Naturally also in hazardous locations.

Universal adaptation to retractable fittings
The modular structure of the Uniclean system allows any retractable fittings to be used. Optimum functionality is achieved with the Ceramat and SensoGate sensor lock-gates.

Highly accurate measurements
The Uniclean 900 system allows highly accurate measurements to be taken even under difficult process conditions such as high pressure, high temperatures, and high levels of impurities. The device can be installed next to the process, within the hazardous area. Control is via the Protos 4400 measuring system or directly via a PLC.

Clean and safe construction
All features for smooth, safe, and low-maintenance operation are included as standard: Water pressure gauge, air filter and water trap, flooding sensor in the housing with alert message.

We look forward to hearing from you!
Contact Us

Technical details

Explosion protection: Ex, hazardous area Zone 1
Enclosure: Stainless steel, coated
Protection: IP 65/NEMA 4X

Downloads

Manuals

[3986] User Manual
Uniclean 900(X) Probe Controller
Version 07
[14190] User Manual
ZU 0741 (PFA, PVDF, PTFE)
Chemical Pump for Probe Controllers Uniclean 900(X), Unical 9000(X)
Version 03
[14286] User Manual
ZU 0812/*, ZU 1067/*
ZU 0812/* Multiplug Bottom Section Conversion Kit / ZU 1067/* Multiplug Middle Section Conversion Kit
Version 02
[14145] User Manual
ZU 0741/1 (PTFE, stainless steel (1.4408, 1.4401)
Chemical Pump for Probe Controllers Uniclean 900(X), Unical 9000(X)
Version 04

Data Sheets

[3975] Data sheet
Uniclean 900
Product Description | Specifications | Product Range

Certificates

[17571] Certificate of Conformity (FM-US)
Unical 9000-X, Uniclean 900-X
Hazardous Location Electrical Equipment
No.3024483 | 2022-12-08
[13926] EU Declaration of Conformity (DE, EN, FR)
No. EU230413A | 2023-04-21
Unical 9000-X | Uniclean 900-X
[12576] Certitficate of Conformity (China - Ex NEPSI)
No. GYJ20.1055 | 2020-08-20
Unical 9000 X, Uniclean 900 X
[18019] Certificate of Conformity (FM-CA)
Unical 9000-X, Uniclean 900-X
Hazardous Location Electrical Equipment per Canadian Requirements
No. FM22CA0056 | 2022-12-08
[18020] IECEx Certificate of Conformity
Types Unical 9000-X… and Uniclean 900-X…
No.: IECEx DEK 22.0022 | 2022-07-28
Issue No. 0
[7720] EU Type-Examination Certificate
Unical 9000-X... and Uniclean 900-X...
KEMA 04 ATEX 1036
Issue Number 5 | 2022-07-28

Control Drawings

[16563] Control Drawing
Unical 9000-X… / Uniclean 900-X…
Zeichnungsnummer 207.001-066 page 2a-2b rev.0
cFMus
[16569] Control Drawing
Unical 9000-X… / Uniclean 900-X…
Zeichnungsnummer 207.001-066 page 1a-1b rev.0
ATEX, IECEx

Our service

Used in Process or Applications

pH value measurement in the pre-scrubber, the neutralization phase, and the lime scrubber as part of the flue gas desulfurization process in power plants.
High quality requirements are placed on raw milk, and online monitoring of truck unloading procedure at the dairy prevents inferior quality (sour milk) from spoiling the entire stock of the storage tank.

Related Products

Relevant Blog Posts

Stack and String Voltage Measurement in Electrolyzers and Fuel Cells

Voltage, current and temperature measurement in electrolyzers with P40000 series high voltage transducers

New 30 mV Shunt Resistors for Knick Transducers

Knick is expanding the accessory range for its high-voltage transducers with immediate effect by adding shunt resistors with a 30 mV voltage drop
Innovations at InnoTrans 2024

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

P52000VPD voltage presence detector reliably detects voltages up to 4200 V DC

The new P52000VPD voltage presence detector reliably monitors areas with high voltages and sends a signal to the downstream plant control system when a specified threshold value is reached.

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

Quadruple Standard Signals in Just One Signal Conditioner

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Pulse frequency conditioner for speed sensors

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

Worldwide smallest transducer up to ±2200 V

The P40000 series from Knick enables reliable voltage measurements from ±50 mV to ±3600 V and current measurements from ±100 mA to ±20 kA.

Importance of broad-range power supplies for DC electrical measurement

Many DC electrical measurement products manufactured by Knick contain universal, also known as broad-range, power supplies.

Measuring Photovoltaic Degradation

Photovoltaic (PV) array degradation is an important aspect to consider for system design and installation.

Electrical Measurement Solutions: Control from 480 to 4800 Volts

Voltage and current transducers from Knick bring true control to electrical measurement applications across a wide-range of industries.

Benefits of High Voltage Transducers versus Instrument Transformers

When a need arises to step voltage in a circuit either up or down for purposes of power transmission or distribution, there is no doubt that transformers are essential.

Shunt Resistor versus Hall Effect Technology

There are many systems where measurement of large DC currents are needed for performance and safety.

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.