Skip to main content

WG25 Repeater Power Supply, Loop-powered | Ex | HART Signal Transmission

Description

WG25 Repeater Power Supply, Loop-powered | Ex | HART Signal Transmission

For supply of intrinsically safe 2-wire transmitters and SMART transmitters.

  • Affordable
    Good price due to omission of integrated power supply
  • No mains supply required
    Cost savings due to lower wiring effort, no mains influences
  • Low power losses
    No unnecessary heating in the enclosure
  • Protective separation
    according to EN 61140 Protection of maintenance staff and downstream devices against excessively high voltages
  • HART transmission
    Bidirectional point-to-point transmission of digital data according to the HART specification
  • EMC tested
    RFI suppressed and surge proof, reliable operation even with electromagnetic interference
  • Maximum reliability
    No maintenance work, therefore the related costs are not incurred

The Task
The passive WG25 repeater power supply is loop-powered. It is used for galvanic hazardous-area separation of a 2-wire supply line and transmits both 4 ... 20 mA and HART signals in both directions. With a voltage drop of just 4.2 V, the WG 25 uses the supply optimally so that all common 2-wire transmitters can be connected.

The Advantages
Compared with active repeater power supplies, it has considerable price and reliability advantages. 
Multi-channel systems, for example, require only one central, safe-area power supply that does not even need protective separation.

The Technology
Using Knick TransShield technology, the WG25 has specifications that were previously not available in passive repeater power supplies:

  • Extremely high reliability, MTTF of over 300 years
  • Protective separation, transient protection
  • 10 kV test voltage (optional)
  • High electromagnetic compatibility
  • Extremely low residual ripple and common-mode interference
  • Outstanding pulse formation
  • HART transmission
  • Hazardous/safe area separation

We look forward to hearing from you!
Contact Us

Technical details

Communication (Output, Digital): HART
Function: Signal transmission and supply of 2-wire sensors
Input: 4 ... 20 mA
Explosion protection: Ex
Output: 4 ... 20 mA
Isolation AC/DC: up to 1,000 V
Test Voltage: 4 kV AC
Power Supply: Loop powered
Ambient operating temperature: –10 ... 50 °C
Dimensions (W x L x H): 22.5 x 73.5 x 118.2 mm
Special features: ATEX: II (1) G [EEx ia] IIC, Transmission of HART signals
Product Category: Isolated Signal Conditioner

Downloads

Manuals

[4502] User Manual (DE, EN)
WG 25
Loop-Powered Supply
Version 04

Data Sheets

[4397] Data Sheet
WG25
Product Description | Specifications | Product Range

Certificates

[13687] EU Declaration of Conformity (DE, EN, FR)
WG 25 A7, Opt. ... & IsoTrans 37 A7, Opt. ...
No. EU210416A | 2021-04-16

Our service

Used in Process or Applications

High voltage transducers and signal conditioners for the acquisition and conversion of current, voltage, temperature, speed, strain and resistance signals.

Related Products

Relevant Blog Posts

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

Successful joint project : Knick developed the special Ceramat WA 155 retractable fitting for optical probes from SOPAT

In cooperation with SOPAT, Knick developed a special Ceramat fitting for optical probes for automatic cleaning in fouling processes.

High-quality immersion fitting for mobile applications

ARD 170 enables measurements even in deep water

Modular immersion fitting as an electrically conductive variant

Knick is expanding its portfolio of fittings for liquid analysis with additional electrically conductive (EL) variants.

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.