Hellma Spectroscopy Probes and Knick Retractable Fittings

Achema 2024 was the premiere of the sales cooperation between Knick and Hellma. The German companies Hellma and Knick are market leaders and global players with premium-quality products and proven technologies. Both companies want to provide the process technology market a coordinated solution with selected products to make production and manufacturing processes more efficient and safer.
A Strong Team for More Efficiency and Safety in Production and Manufacturing Processes with Spectroscopy Analytics
The presented bundles consisting of a Falcata spectroscopy probe and Knick's Ceramat and SensoGate retractable fittings enable quantifiable increases in efficiency and greater process reliability, even in the most challenging processes. Customers therefore benefit from a comprehensive and integrated advice for their application which takes all relevant parameters into account. Projects and inquiries can thus be realized more quickly and in a more targeted manner.
Retractable fittings from Knick and spectroscopy probes from Hellma
UV/Vis/NIR probes and measurement cells are already an integral part of modern process analytical technology. Optical spectroscopy helps to keep an eye on production processes and quality control. The key to success is a precise yet robust spectroscopic process interface using optical immersion probes that are integrated directly into the running process and generate relevant process data from the measuring point in real time. As good as efficiency and quality increases can already be achieved at this point, the effect is noticeably improved with a retractable fitting.
Thanks to the unique interlock principle of the Knick Ceramat as well as the SensoGate retractable fitting, optical probes can be coupled and uncoupled without interrupting the ongoing process. The joint use of an optical probe and retractable fitting is particularly suitable for harsh applications or applications in adverse process conditions. The Ceramat has a unique, automatic cleaning function that allows the probe to be uncoupled from the running process and cleaned inside the retractable fitting. These cleanings can be carried out automatically and cyclically while the process continues to run.
Referencing, maintenance, replacement and cleaning without process interruption
When applying spectroscopic methods, it is necessary, regardless of the measuring system used, to perform reference measurements without a medium or with a reference medium and to repeat them at regular intervals. Until now, spectroscopy probes had to be laboriously removed and cleaned for this purpose. For products that tend to stick, there is also an increased need for cleaning to reduce the risk of incorrect measurements. The solution to these and other challenges is high-quality retractable fittings from Knick, which allow safe and convenient handling while the process is running.
Combination of optical probe and retractable fitting provides clear efficiency benefits
This means, for example, that a reference measurement can be carried out at any time during the ongoing process. A probe can be cleaned in CIP mode (Cleaning in Place), i.e. it can be cleaned on site without having to be laboriously removed. The process does not have to be stopped during probe maintenance or replacement and can continue. This improves the output of the system and reduces waste through continuous process monitoring. A large variety of process connections allows adaptation to different conditions.
About Hellma GmbH & Co. KG
Hellma is an independent supplier and world leader in spectroscopic analytical solutions and has been the leading manufacturer of precision optical products made of glass and quartz glass for UV/Vis/NIR spectroscopy for over 100 years. Customers from industry and research worldwide value Hellma products for their high quality and reliability. In a wide range of process and laboratory applications, their high precision guarantees the best and reproducible measurement results in analytics.
Download Flyer

Latest Posts
Process Analytics
Pharma, Sensor, Conductivity
Interface Technology
Hydrogen
Interface Technology
Interface Technology
Exhibition, InnoTrans
Process Analytics
Fitting, Achema
Related Posts

Mar 2025
Process Analytics
Pharma, Sensor, Conductivity
SE605H Conductivity Sensor with CondCheck

Jul 2024
Process Analytics
Achema, Fitting
Hellma Spectroscopy Probes and Knick Retractable Fittings

Jul 2024
Process Analytics
Achema
ACHEMA 2024 - Review and Impressions

Feb 2024
Process Analytics
Uniclean700, Launch
Uniclean 700 Series - Modular control system for automated sensor cleaning

Apr 2023
Process Analytics
Fitting, Launch, WA111
Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

Apr 2023
Process Analytics
Fitting, Launch, WA155
Successful joint project : Knick developed the special Ceramat WA 155 retractable fitting for optical probes from SOPAT

Apr 2023
Process Analytics
Conductivity, Phamacy, pH
pH and conductivity measurement in vaccine production

Apr 2023
Process Analytics
Sensor, Conductivity, SE625
Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

Jan 2023
Process Analytics
ARD75
Sensor Adapter with Lock Function Enables Safe and Thorough Cleaning

Nov 2022
Process Analytics
Protos II 4400, Module
Up to six Sensors on one Transmitter Protos II 4400 via Modul MSU4400-180

Aug 2022
Process Analytics
Achema, Exhibition
ACHEMA 2022 - Knick at the world forum for the process industry

Jun 2022
Process Analytics
Sensor, pH, SE555, ORP
Combined pH- and ORP-Sensor SE555X/*-AMSN

Apr 2022
Process Analytics
MemoTrans
Ultra Compact Transmitter for Memosens Sensors

Feb 2022
Process Analytics
Protos II 4400, Stratos Multi, Software, ProgaLog
Conveniently configure transmitters offline on a PC - ProgaLog 4000

Feb 2022
Process Analytics
Stratos Multi, Transmitter
New Stratos Multi E461N transmitter with Profinet

Jan 2022
Process Analytics
Memosens
Memosens 2.0: Evolution of digital data transfer

Nov 2021
Process Analytics
Sensor, Conductivity, Ex, SE656, SE655
SE655X Digital and SE656X Digital - Digital Conductivity Sensors with Ex Certification

Nov 2021
Process Analytics
Exhibition, Switzerland, Ilmac
ILMAC 2021 in Basel - Trade Show Review by Knick Schweiz AG

Oct 2021
Process Analytics
Stratos Multi, Transmitter, Ex
Stratos Multi E401X- Multiparameter Transmitter for Hazardous Locations

May 2021
Process Analytics
Transmitters, Stratos Multi
Stratos Multi E471 with EtherNet/IP for process optimization

May 2021
Process Analytics
Sensor, Conductivity, Launch, SE656
New SE656N digital conductivity sensor

Mar 2021
Process Analytics
Protos II 4400, Profinet
Transmitter for the process industry with PROFINET module

Jul 2020
Process Analytics
Fitting, Launch, ARD170
High-quality immersion fitting for mobile applications

Jul 2020
Process Analytics
Fitting, ARD50, ARD75
Modular immersion fitting as an electrically conductive variant

Apr 2020
Process Analytics
Launch, Transmitters, Stratos Multi
New multiparameter transmitter Stratos Multi

Feb 2018
Process Analytics
Sensor, Fitting
How to get the sensor into the process

Apr 2017
Process Analytics
MemoRail Modbus
Powerful compact analyzer boosts performance while reducing costs

Feb 2017
Process Analytics
Conductivity
High-Precision Conductivity Measurement at Extreme Temperature Differences

Nov 2016
Process Analytics
Transmitter, FF, Profibus, HART