Product added to compare
Product Compare added Product Compare

37 Isolated Standard Signal Conditioner | Input 0(4) … 20 mA | Ex | Transmission of HART signals | Loop-Powered

Description

37 Isolated Standard Signal Conditioner | Input 0(4) … 20 mA | Ex | Transmission of HART signals | Loop-Powered

For safe-area/hazardous-area isolation of 0 ... 20 mA standard signals without power supply

  • Galvanic isolation between input and output signal
    Protection against measuring errors caused by grounding problems and parasitic interference voltages
  • No power supply required
    Cost savings due to lower wiring effort, no mains interference
  • Very low residual ripple
    No interference of the connected measuring or control system
  • Explosion protection according to ATEX
  • High transmission accuracy
    Excellent pulse formation due to exact transmission of the measured values
  • Very low common-mode interference
    Prevention of incorrect measurements or failures caused by interference
  • Maximum reliability
    No repair or failure costs
  • 10 kV test voltage
    (optional)
  • Protective separation according to EN 61140
    Protection of the maintenance staff and subsequent devices against excessively high voltages
  • SMART transmission
    Bi-directional point-to-point transmission of digital data according to the HART specification
  • 5-year warranty

Knick loop-powered isolators for 0 ... 20 mA signal transmission. These modules are available as hazardous-area input and hazardous-area output isolators. Due to their patented design (German patent 3526997), they are considered to be the most reliable solution for isolating standard signals without an external power supply.

The 37A7 isolators are not only suitable as highly reliable isolators for normal applications, they also meet the most stringent requirements that can be set for potential isolation. There is no need for power supply wiring.

여러분의 의견을 기다리겠습니다!
문의하기

기술 세부 정보

통신(출력, 디지털): HART
폭발 방지: Ex
제품 카테고리: 범용 아이솔레이터 / 표준 신호 아이솔레이터

다운로드

사용 설명서 (매뉴얼)

[14276] User Manual (DE, EN)
37 Isolated Standard Signal Conditioner
Version 02

브로셔

[14160] 브로셔
제품 개요 인터페이스 기술

Software

[11876] Knick Produktmakros (.pdf)
ePLAN Electric P8
[12154] Software (.zip)
ePLAN P8 Produktmakros

서비스

프로세스 또는 애플리케이션에서 사용

전류, 전압, 온도, 회전 속도, 변형 및 저항 신호의 측정과 변환을 위한 고전압 절연 증폭기 및 트랜스미터.

관련 제품

관련 블로그 게시물

Stack and String Voltage Measurement in Electrolyzers and Fuel Cells

Voltage, current and temperature measurement in electrolyzers with P40000 series high voltage transducers

크닉 트랜스미터를 위한 새로운 30mV 분로 저항기

크닉은 이제 전압 강하가 30mV인 분로 저항기를 포함하도록 고전압 트랜스미터용 액세서리 제품군을 확장함
Innovations at InnoTrans 2024

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

전압 검출기 P52000VPD는 최대 4200 V DC까지 전압을 안정적으로 감지합니다.

새로운 전압 감지기 P52000VPD(전압 존재 감지)는 고전압 영역을 안정적으로 모니터링하고 전압이 지정된 임계값에 도달하면 신호를 다운스트림 시스템 제어 장치로 전송합니다.

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

VariTrans A20340 - 단 하나의 절연 증폭기에서 표준 신호 4배율

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Pulse frequency conditioner for speed sensors

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

±2200 V까지 사용할 수 있는 세계에서 가장 작은 절연 증폭기

저희 Knick의 VariTrans P 40000 시리즈를 통해 ± 50 mV에서 ± 3600 V까지의 전압과 ± 100 mA에서 ± 20 kA까지의 전류의 안정적인 측정이 가능합니다. 이미 입증된 ProLine 제품군에 DIN 레일 설치를 할 수 있도록 작은 외함을 가진 절연 증폭기 P42000D2가 추가됐습니다.

Importance of broad-range power supplies for DC electrical measurement

Many DC electrical measurement products manufactured by Knick contain universal, also known as broad-range, power supplies.

Measuring Photovoltaic Degradation

Photovoltaic (PV) array degradation is an important aspect to consider for system design and installation.

Electrical Measurement Solutions: Control from 480 to 4800 Volts

Voltage and current transducers from Knick bring true control to electrical measurement applications across a wide-range of industries.

Benefits of High Voltage Transducers versus Instrument Transformers

When a need arises to step voltage in a circuit either up or down for purposes of power transmission or distribution, there is no doubt that transformers are essential.

Shunt Resistor versus Hall Effect Technology

There are many systems where measurement of large DC currents are needed for performance and safety.

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.