Saltar al contenido principal Saltar a la búsqueda Saltar a la navegación principal

Data Center: Knick Delivers Robust Electrical Measurement Solutions

The rapid growth of data centers, fueled by AI and high-performance computing, is driving a shift toward high-voltage DC architectures to address challenges with increasing power density. Microgrids and DC energy sources are becoming critical to support capacity-limited grids and meet the growing power demands forecasted for the industry. Accurate, fast, and isolated electrical measurements are foundational to these new architectures, enabling safe, scalable, and reliable operation across evolving data center power systems.

Power at Scale: Designing for AI-Driven Demand Today

Exponential growth of AI and cloud-based services are driving unprecedented power demand in data centers.

To meet these demands, data centers are beginning to shift away from traditional 480 V AC distribution. Facilities are now being designed with 800 V DC architectures, which reduces current, lowers copper requirements, and decreases the need for AC/DC converters throughout the facility, including at each rack—helping to cut capital costs. This approach also enables direct integration of battery energy storage and renewable sources into the power network, creating new opportunities for flexible and scalable power delivery.

However, these evolving high-voltage DC designs introduce new measurement and protection challenges. Robust, electrical isolation must be engineered in to safeguard controls, personnel, and downstream electronics while fast, precise measurement for optimization and feedback control is ensured. Devices must deliver long service lives with minimal maintenance or recalibration, as downtime has significant financial impact.

Knick’s solutions meet these demands with flexible, isolated, and future-ready measurement devices. Off-the-shelf transducers designed for applications at and above the 800 V architecture simplify integration, allowing data centers to scale safely and efficiently without long qualification cycles.

Sector 1

Sector 2

Sector 3

Sector 4

Why Knick?
Knick provides high-isolation measurement solutions built for modern DC data center architectures. High-voltage transducers deliver fast, accurate data for dynamic loads, ensuring reliable control, protection, and optimization. Commercial off-the-shelf products are ready for immediate deployment and easily configurable for future expansions, supporting system-agnostic integration. With decades of experience in high-voltage DC power distribution, Knick devices combine precision, durability, and high-voltage capability to help future-proof infrastructure. No matter the system requirement, operators can rely on safe, accurate monitoring within their data center power delivery systems.

Technology Highlight – Fault Protection with High Speed Circuit Breakers

High-speed circuit breakers are critical for protecting data center power systems from fault conditions. Accurate voltage and current measurements serve as the primary inputs for protection and trip logic, providing the real-time electrical data needed to detect overcurrent, overvoltage, or other abnormal events.

Knick’s transducers are designed to meet these demanding requirements. With microsecond-level response times, they enable rapid fault detection and trigger protective actions before damage occurs. High, 3-port galvanic isolation ensures downstream control and relay electronics remain safe during fault events, while stable, accurate signals help prevent false tripping that could interrupt operations. Their configurable, system-agnostic design also allows integration across a variety of DC architectures, making it easier for operators to deploy reliable protection as facilities scale and evolve.

For data center operators, this translates into improved system reliability and confidence in protection strategies as DC voltages and power densities continue to rise. By integrating Knick measurement technology with high-speed breakers, facilities can maintain operation while safely scaling to meet the growing demands of AI workloads and high-density power architectures.

H2 [Ind] Video Title

Absatz [Ind] Short description of the video

Ausgeblendet

Productos


Descargar el folleto del producto: Con su amplia gama de acondicionadores de señal y transductores, Knick ofrece soluciones que cumplen las normas más estrictas de seguridad, precisión, robustez y durabilidad.

Ausgeblendet

Related Applications

Have a question? We are here to help.
Contact Us

Blog Articles

The Power Behind Data AI & Data Centers

Empower AI with precision: High-voltage measurement solutions from Knick deliver real-time, reliable data.

Medición de temperatura altamente aislada en KEMA Labs

Medición de temperatura segura y precisa para tareas de comprobación exigentes en entornos de alta tensión.

Medición con seguridad funcional de altas tensiones en aplicaciones industriales

Transductor de alta tensión para 3900 V CC y 4500 V CApico

Modernización de la infraestructura ferroviaria con transductores de alta tensión de Knick y sistemas DAQ de Dewesoft

Un proyecto ferroviario conjunto con Dewesoft demuestra que: la serie P40000 de Knick ofrece la máxima flexibilidad posible.

P45000 SIL 2 / SIL 3: Voltage measurements in applications with functional safety

Knick ofrece una nueva solución con futuro asegurado para infraestructuras energéticsa modernas: de forma fiable, flexible y segura.

Stack and String Voltage Measurement in Electrolyzers and Fuel Cells

Voltage, current and temperature measurement in electrolyzers with P40000 series high voltage transducers

Nuevas resistencias shunt de 30 mV para transductores de Knick

Knick amplía desde ya su oferta de accesorios para transductores de alta tensión con resistencias shunt con una caída de tensión de 30 mV
Innovations at InnoTrans 2024

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

P52000VPD voltage presence detector reliably detects voltages up to 4200 V DC

The new P52000VPD voltage presence detector reliably monitors areas with high voltages and sends a signal to the downstream plant control system when a specified threshold value is reached.

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

Quadruple Standard Signals in Just One Signal Conditioner

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Pulse frequency conditioner for speed sensors

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

Worldwide smallest transducer up to ±2200 V

The P40000 series from Knick enables reliable voltage measurements from ±50 mV to ±3600 V and current measurements from ±100 mA to ±20 kA.

Importance of broad-range power supplies for DC electrical measurement

Many DC electrical measurement products manufactured by Knick contain universal, also known as broad-range, power supplies.

Measuring Photovoltaic Degradation

Photovoltaic (PV) array degradation is an important aspect to consider for system design and installation.

Electrical Measurement Solutions: Control from 480 to 4800 Volts

Voltage and current transducers from Knick bring true control to electrical measurement applications across a wide-range of industries.

Benefits of High Voltage Transducers versus Instrument Transformers

When a need arises to step voltage in a circuit either up or down for purposes of power transmission or distribution, there is no doubt that transformers are essential.

Shunt Resistor versus Hall Effect Technology

There are many systems where measurement of large DC currents are needed for performance and safety.

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.