跳到主要内容 跳到搜索 跳到主导航

Data Center: Knick Delivers Robust Electrical Measurement Solutions

The rapid growth of data centers, fueled by AI and high-performance computing, is driving a shift toward high-voltage DC architectures to address challenges with increasing power density. Microgrids and DC energy sources are becoming critical to support capacity-limited grids and meet the growing power demands forecasted for the industry. Accurate, fast, and isolated electrical measurements are foundational to these new architectures, enabling safe, scalable, and reliable operation across evolving data center power systems.

Power at Scale: Designing for AI-Driven Demand Today

Exponential growth of AI and cloud-based services are driving unprecedented power demand in data centers.

To meet these demands, data centers are beginning to shift away from traditional 480 V AC distribution. Facilities are now being designed with 800 V DC architectures, which reduces current, lowers copper requirements, and decreases the need for AC/DC converters throughout the facility, including at each rack—helping to cut capital costs. This approach also enables direct integration of battery energy storage and renewable sources into the power network, creating new opportunities for flexible and scalable power delivery.

However, these evolving high-voltage DC designs introduce new measurement and protection challenges. Robust, electrical isolation must be engineered in to safeguard controls, personnel, and downstream electronics while fast, precise measurement for optimization and feedback control is ensured. Devices must deliver long service lives with minimal maintenance or recalibration, as downtime has significant financial impact.

Knick’s solutions meet these demands with flexible, isolated, and future-ready measurement devices. Off-the-shelf transducers designed for applications at and above the 800 V architecture simplify integration, allowing data centers to scale safely and efficiently without long qualification cycles.

Sector 1

Sector 2

Sector 3

Sector 4

Why Knick?
Knick provides high-isolation measurement solutions built for modern DC data center architectures. High-voltage transducers deliver fast, accurate data for dynamic loads, ensuring reliable control, protection, and optimization. Commercial off-the-shelf products are ready for immediate deployment and easily configurable for future expansions, supporting system-agnostic integration. With decades of experience in high-voltage DC power distribution, Knick devices combine precision, durability, and high-voltage capability to help future-proof infrastructure. No matter the system requirement, operators can rely on safe, accurate monitoring within their data center power delivery systems.

Technology Highlight – Fault Protection with High Speed Circuit Breakers

High-speed circuit breakers are critical for protecting data center power systems from fault conditions. Accurate voltage and current measurements serve as the primary inputs for protection and trip logic, providing the real-time electrical data needed to detect overcurrent, overvoltage, or other abnormal events.

Knick’s transducers are designed to meet these demanding requirements. With microsecond-level response times, they enable rapid fault detection and trigger protective actions before damage occurs. High, 3-port galvanic isolation ensures downstream control and relay electronics remain safe during fault events, while stable, accurate signals help prevent false tripping that could interrupt operations. Their configurable, system-agnostic design also allows integration across a variety of DC architectures, making it easier for operators to deploy reliable protection as facilities scale and evolve.

For data center operators, this translates into improved system reliability and confidence in protection strategies as DC voltages and power densities continue to rise. By integrating Knick measurement technology with high-speed breakers, facilities can maintain operation while safely scaling to meet the growing demands of AI workloads and high-density power architectures.

Ausgeblendet

产品概览


下载产品手册: 凭借种类齐全的隔离放大器和测量变送器,克尼克可提供符合安全、精确、坚固和耐用最高标准的解决方案。

Ausgeblendet

Related Applications

Have a question? We are here to help.
Contact Us

Blog Articles

The Power Behind Data AI & Data Centers

Empower AI with precision: High-voltage measurement solutions from Knick deliver real-time, reliable data.

KEMA 实验室的高绝缘温度测量方案

胜任高压严苛测试,保障温度测量安全与精准。

Functionally safe measurement of high voltages in industrial applications

适用 3,900 V DC 和 4,500 V ACpeak 的高压测量变送器

使用 Knick 高压隔离放大器和 Dewesoft 数据采集系统改造轨道交通基础设施

在与 Dewesoft 合作完成的一个轨道交通项目中,Knick P40000 系列产品展现出出类拔萃的灵活性。

P45000 SIL 2 / SIL 3: Voltage measurements in applications with functional safety

Knick 致力于以前瞻科技,为未来能源提供稳定可靠、灵活扩展、安全无忧的解决方案。

Stack and String Voltage Measurement in Electrolyzers and Fuel Cells

Voltage, current and temperature measurement in electrolyzers with P40000 series high voltage transducers

适用于 Knick 变送器的新型 30 mV 分流电阻

Knick 从现在起为其高压变送器的附件产品系列增添具有 30 mV 电压降的分流电阻
Innovations at InnoTrans 2024

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

P52000VPD 电压检测器能够可靠检测高达 4200 V 的直流电压

新型电压检测器 P52000VPD (Voltage Presence Detection) 能够可靠监控高压应用领域,在达到指定阈值时向下游设备控制器发送信号。

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

VariTrans A20340 – 仅需一个隔离放大器的标准信号倍增

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Pulse frequency conditioner for speed sensors

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

全球最小传感器,高达±2200 V

Knick的VariTrans P 40000系列能对从±50 mV到±3600 V的电压,以及从±100 mA到±20 kA的电流进行可靠测量。经过验证的ProLine系列现在已经扩展到包含传感器P42000D2,它安装在Din导轨上,模块设计紧凑,测量高达2200 V的直流电压。

宽范围电源对于直流电气测量的重要性

Knick生产的众多直流电气测量产品都包含通用的,也称为宽范围电源。这意味着它们将工作在一个相对较宽的电压范围窗口内,如20…253V,交流或直流。

Measuring Photovoltaic Degradation

Photovoltaic (PV) array degradation is an important aspect to consider for system design and installation.

Electrical Measurement Solutions: Control from 480 to 4800 Volts

Voltage and current transducers from Knick bring true control to electrical measurement applications across a wide-range of industries.

Benefits of High Voltage Transducers versus Instrument Transformers

When a need arises to step voltage in a circuit either up or down for purposes of power transmission or distribution, there is no doubt that transformers are essential.

分流器和霍尔效应的技术对比

在许多系统中,为了确保性能和安全,需要测量较大的直流电流。两个例子是静态励磁和轨道牵引动力。这些电流的测量通常采用两种主要原理之一:配有mV级变送器的分流器电阻或霍尔效应传感器来反馈。

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.