Skip to main content Skip to search Skip to main navigation

Precise Voltage, Current, and Temperature Monitoring in Electrolyzer and Fuel Cell Systems

High-isolation measurement for stack/string monitoring in H2 applications

As hydrogen plays an increasingly important role in energy storage and transport, maintaining efficiency and safety in electrolyzer and fuel cell systems is more critical than ever. These systems operate at high DC voltages and require accurate, real-time monitoring to function effectively. Continuous measurement at both the stack and string levels supports predictive maintenance and enhances overall system reliability. Knick’s transducers are specifically designed to meet these demands, offering high working isolation that exceeds typical system voltages and delivering the long-term reliability needed to ensure safe, uninterrupted operation.

Key facts about the application

Sector

Electrolyzer Control & Fuel Cell Monitoring

Application

Voltage, current, and temperature monitoring in electrolyzer or fuel cell stacks and strings

Measured Parameters

DC voltage, current, and temperature to ensure safe and efficient hydrogen production and conversion into electrical energy

Main Requirements

High isolation up to stack/string level, continuous monitoring, long-term stability, safety compliance, no recalibration

Description and requirements

Modern electrolyzers and fuel cells are built by wiring individual cells in series to form stacks, which are then combined into high-voltage strings. While each cell typically operates around 3 V, total string voltages can reach up to 1500 V DC and continue to rise as industry demand grows. To maintain safe and efficient operation, precise monitoring of voltage, current, and temperature at both the stack and string levels is essential for diagnostics and early detection of wear. Without this monitoring, operators risk damaging electrolyzer and fuel cell systems, which can compromise safety and reduce hydrogen production efficiency.

Given the high voltages and potential for voltage surges, measurement equipment must provide strong electrical isolation, not only from the measured signal but also from full system-level potentials. Additionally, the monitoring solution must be durable, maintenance-free, and capable of withstanding environmental stress while ensuring the safety of both operators and equipment.

Why Knick ?
Knick’s transducers deliver high performance measurement with industry leading continuous isolation up to 3.6 kV, exceptional long-term stability, and a compact DIN rail design making them well-suited for integration into electrolyzer and fuel cell systems. They provide accurate voltage, current, and temperature monitoring without the need for recalibration and are supported by a field-proven MTBF rated in the hundreds of years. Built to withstand high potential and noise-heavy environments, these transducers ensure safe, interference free operation. For applications requiring functional safety, Knick also offers SIL rated monitoring solutions to support compliance with evolving hydrogen system standards.

Conclusion

With Knick transducers, operators can reliably monitor electrolyzer and fuel cell performance at both the stack and string levels, enabling early detection of degradation and preventing costly failures. This level of insight supports predictive maintenance strategies, maximizes system uptime, and ensures safe, continuous operation in demanding hydrogen applications.

Knick delivers the clarity and confidence needed for high voltage measurements by combining advanced isolation, long-term stability, and precision. Our commitment to safety, accuracy, and performance makes Knick a trusted partner in the evolving hydrogen energy landscape.

Associated industries and applications

因其隔离性和可靠性出色,Knick 高压变送器和隔离放大器已在众多氢能应用中经受了考验。
我们的高压变送器系列为电池单体、电堆或组串层级电池系统的安全测试和持续监测提供成熟的解决方案。
ehemals H4 Titel z.B. E-Mobility Broschüre

Titel des Dokuments (de) Donec pede justo, fringilla vel, aliquet nec, vulputate eget, arcu. In enim justo, rhoncus ut, imperdiet a, venenatis vitae, justo

Latest blog post

Stack and String Voltage Measurement in Electrolyzers and Fuel Cells

Voltage, current and temperature measurement in electrolyzers with P40000 series high voltage transducers

适用于 Knick 变送器的新型 30 mV 分流电阻

Knick 从现在起为其高压变送器的附件产品系列增添具有 30 mV 电压降的分流电阻
Innovations at InnoTrans 2024

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

P52000VPD 电压检测器能够可靠检测高达 4200 V 的直流电压

新型电压检测器 P52000VPD (Voltage Presence Detection) 能够可靠监控高压应用领域,在达到指定阈值时向下游设备控制器发送信号。

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

VariTrans A20340 – 仅需一个隔离放大器的标准信号倍增

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Pulse frequency conditioner for speed sensors

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

全球最小传感器,高达±2200 V

Knick的VariTrans P 40000系列能对从±50 mV到±3600 V的电压,以及从±100 mA到±20 kA的电流进行可靠测量。经过验证的ProLine系列现在已经扩展到包含传感器P42000D2,它安装在Din导轨上,模块设计紧凑,测量高达2200 V的直流电压。

宽范围电源对于直流电气测量的重要性

Knick生产的众多直流电气测量产品都包含通用的,也称为宽范围电源。这意味着它们将工作在一个相对较宽的电压范围窗口内,如20…253V,交流或直流。

Measuring Photovoltaic Degradation

Photovoltaic (PV) array degradation is an important aspect to consider for system design and installation.

Electrical Measurement Solutions: Control from 480 to 4800 Volts

Voltage and current transducers from Knick bring true control to electrical measurement applications across a wide-range of industries.

Benefits of High Voltage Transducers versus Instrument Transformers

When a need arises to step voltage in a circuit either up or down for purposes of power transmission or distribution, there is no doubt that transformers are essential.

分流器和霍尔效应的技术对比

在许多系统中,为了确保性能和安全,需要测量较大的直流电流。两个例子是静态励磁和轨道牵引动力。这些电流的测量通常采用两种主要原理之一:配有mV级变送器的分流器电阻或霍尔效应传感器来反馈。

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.