P16000 Pulse Frequency Conditioner | Input speed sensor signal up to 20kHz | Safe decoupling acc. SIL3
Description
The ProLine P 16000 receives signals from speed sensors and transmits and converts them into electrically isolated analog standard signals.
- Pulse frequency measurement, e.g., of speed sensors / rotary encoders for safe detection of the train’s speed or standstill; galvanic isolation and
- conversion into standard signals; measuring ranges: 0 ... 500 Hz to 0 ... 20 kHz.
- Converting the pulse frequency into a standard signal eliminates the need for pulse counting inputs at the control unit.
- Safety-related signals from existing circuits can be duplicated without interaction and can be transmitted to another subsystem.
- The absence of interaction is designed to be functionally safe and achieves SIL 3.
- 5-year warranty
The input is designed in a way that it can “tap” signals from existing circuits without disturbing the original signal. This absence of interaction complies with the SIL 3 integrity level according to EN 61508.
Even a safety-oriented signal from a sensor can be duplicated and transmitted to a second controller without any interaction.
The product is resistant against the harsh environmental conditions typical of rolling stock applications. The device functionality is not affected by electromagnetic interferences, extreme ambient temperatures or vibration and shock. The latest fire safety regulations for rail vehicles are met.
Standards
- Use on rolling stock – EN 50155
- Power supply – EN 50155 (S2), RIA12/1984)
- Fire protection (HL3) – EN 45545-2
- Functional safety – EN 61508
- Reliability (MTBF) – EN 61709
- Protection against electric shock – EN 61140
- Vibration / Shock (Category 1, Class B) – EN 61373 (IEC 61373)
- EMC—railway applications – EN 50121-1, EN 50121-3-2
- EMC—industrial applications – EN 61326-1
- Temperature class TX (-40…+85 °C) – EN 50155 / EN 50125-1 and EN 50125-2
- Altitude class AX (2000 m or 4000 m AMSL) – EN 50155 / EN 50125-1 and EN 50125-2
- Insulation coordination for railway and industry -EN 50124-1, EN 61010-1
- Electrical safety and fire protection USA – UL 61010-1
我们期待您的来信
联系我们
AC/DC 电位隔离: | 最高 300 V |
---|---|
工作环境 温度: | –40 ... 70 °C |
输入: | 0 ... 0.5 kHz, 0 ... 1 kHz, 0 ... 2 kHz, 0 ... 5 kHz, 0 ... 10 kHz, 0 ... 20 kHz, 转速传感器信号 |
输出: | 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA |
最小测试电压: | 3 kV AC |
电源: | 24 ... 110 V DC |
尺寸(宽 x 长 x 高): | 12.5 x 99 x 114.5 mm |
特点: | 信号倍增后,无需加装旋转编 码器, 安全解耦级别达 SIL 3 (IEC 61508), 将安全相关编码器信号与现有测 量电路解耦,以记录列车速度 |
产品类别: | 信号倍增器, 测量变送器 |