Stratos Pro A201 PH pH/ORP Transmitter | Analog Sensors | Ex Zone 2 | HART | 2x 4 ... 20 mA Outputs

2-wire-transmitter for pH and ORP measurement

  • Operation in hazardous areas
  • Two current outputs
  • Digital communication: HART 
  • Intuitive operation with color-coded user guidance
  • IP 66/67, NEMA 4X protection
  • Automatic sensor identification
  • Sensor diagnostic with wear indication, remaining lifetime, CIP/SIP counter and adaptive calibration timer
  • High-contrast widescreen display with colored backlighting
  • Protective pane made of safety glass
  • One analog input (4 ... 20 mA) e.g. for external pressure compensation
  • Two parameter sets
  • Two digital inputs: 
    • External HOLD activation
    • External switching between parameter set
  • Logbook (200 entries)
Outstanding properties
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
 
Wide Range of Functions
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value. 

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

2 ou 4 fils: 2 fils
Boîtier: Molded enclosure, PBT/PC, glass-reinforced
Canaux: 1 canal
Communication (Sortie numérique): HART
Gamme de produits: Stratos, Stratos Pro
Paramètres de mesure: pH/potentiel redox
Protection contre les explosions: Ex, Ex Zone 2
Raccordement de la sonde: Analogue
Sortie de courant: 2 x 4…20 mA
Sorties de courant: 2x 4 … 20 mA
permanently installed / portable: permanently installed
Écran: Écran graphique couleur TFT 4,3", rétro-éclairé blanc

Téléchargements

Manuals

[3940] Manuel utilisateur
Stratos Pro A201PH
Mesure du pH
Version 05
[16503] Transmitter Specific HART Command Specification
Stratos Pro A201 pH / Stratos Evo A402 pH
Device Revision: 08
[14536] Transmitter Specific HART Command Specification
Stratos Pro A201 PH
Device Revision: 7
[13887] Transmitter Specific HART Command Specification
Stratos Pro A201 PH
Device Revision: 6
[13497] Transmitter Specific HART Command Specification
A211 PH / A411 PH
Device Revision: 2
[13502] Transmitter Specific HART Command Specification
A211 PH / A411 PH
Device Revision: 3
[13662] Transmitter Specific HART Command Specification
Stratos Evo A402 pH / Stratos Pro A201 pH
Device Revision: 5

Brochures

[14695] Brochure
Stratos Pro
2-wire analyzers for pH/ORP, conductivity or oxygen

Fiches techniques

[16180] Data sheet (EN)
Stratos Pro A201
Product Description | Specifications | Product Range

Certificats

[12942] EU Declaration of Conformity (DE, EN, FR)
No. EU220113A | 2022-01-13
for Stratos Pro Type A201B…
[8040] Certificate of Conformity (FM-Canada)
No. FM21CA0052 (Canada) | 2021-11-01
Stratos Pro Types A201X…, A211X…, A201B…, A221X… and A231X… | Stratos Multi Type E401X
[9523] Certitficate of Conformity (China - Ex NEPSI)
Cert No. GYJ20.1053X | 2020-06-10
Stratos Pro A2..B
[17027] EU Type-Examination Certificate
No. KEMA 08ATEX0100 | 2024-03-07
Issue No. 10
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A221X… and A231X… | Stratos Multi Type E401X
[17021] IECEx Certificate of Conformity
No. IECEX KEM 08.0020
Issue No. 9 | 2024-03-07
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A201B…, A221X…, A231X | Stratos Multi Type E401X
[8682] Certificate of Compliance (FM)
No. FM21US0078 | 2023-11-02
Stratos Multi E401X…, Stratos Pro A201X…, A211X…, A201B…, A221X…, A231X
[12917] Quality Control Certificate
Device Settings for Customer-Specific Buffer Solutions
Version 01

Safety guides

[7598] Safety Guide
Stratos Pro / MS / Evo Series
Installation and Use in Hazardous Locations
Version 05

Software

[16497] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 08
[14526] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 07
[13872] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 06
[13468] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 04
[12212] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 03
[16491] EDD (PDM)
Stratos Pro A201 pH
Device Revision 08 (02)
[14531] EDD (PDM)
Stratos Pro A201 pH
Device Revision 07
[13877] EDD (PDM)
Stratos Pro A201 pH
Device Revision 06
[13482] EDD (PDM)
Stratos Pro A201 pH
Device Revision 04
[13477] EDD (PDM)
Stratos Pro A201 pH
Device Revision 03
[12198] EDD (PDM)
Stratos Pro A201 pH
Device Revision 02
[16485] EDD (AMS)
Stratos Pro A201 pH
Device Revision 08 (02)
[14521] EDD (AMS)
Stratos Pro A201 pH
Device Revision 07
[13882 EDD (AMS)
Stratos Pro A201 pH
Device Revision 06
[13460] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 02
[13492) EDD (AMS)
Stratos Pro A201 pH
Device Revision 04
[13487) EDD (AMS)
Stratos Pro A201 pH
Device Revision 03
[12200) EDD (AMS)
Stratos Pro A201 pH
Device Revision 02
[18054] Software
KnUT (Knick Update Tool)

Notre service

Utilisé dans les processus ou les applications

Les tours de refroidissement sont utilisées dans de multiples secteurs industriels pour évacuer la chaleur industrielle des circuits de refroidissement. Les dépôts minéraux et la corrosion diminuent l’efficacité et conduisent à l’usure prématurée des composants des installations.

Produits apparentés

Articles de blog pertinents

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

Coopération réussie : Knick a développé un support rétractable spécial Ceramat WA 155 pour les sondes optiques de SOPAT.

Nettoyage automatique des sondes optiques dans les processus d'encrassement : Un projet commun de Knick et SOPAT pour une application client avec Ceramat.

Canne d’immersion haute qualité pour applications mobiles

Avec l’ARD 170, Knick propose une canne d’immersion haute qualité pour mesures mobiles du pH, de la conductivité et de l’oxygène dissous. Les développeurs ont accordé une attention particulière à la simplicité et la flexibilité d’utilisation.

Canne d'immersion modulaire en version électriquement conductrice

Avec ses cannes d'immersion ARD 50 EL et ARD 75 EL, Knick complète de deux versions électriquement conductrices (EL) son portefeuille de cannes d’analyse de liquides. Les modulaires permettent l’utilisation de sondes spécifiques aux applications.

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.