Passer au contenu principal Passer à la recherche Passer à la navigation principale

SE707 Oxygen Sensor | Memosens | 320 mm | Ex | Measuring range (resolution) 0 ... 50 mg/l (1 μg/l)

Description

SE707 Oxygen Sensor | Memosens | 320 mm | Ex | Measuring range (resolution) 0 ... 50 mg/l (1 μg/l)

Reliable measurement of oxygen traces, also under sterile and hygienic conditions; signal-stable and robust, digital, with Memosens technology.

  • perfect galvanic isolation thanks to Memosens technology
  • precalibration in the lab
  • no influence of humidity in the connector
  • digital data transfer
  • integrated sensor diagnostics
  • high level of process safety
  • durable materials
  • robust design
  • easy to clean thanks to extremely smooth surface
  • very simple calibration in air without calibration gases
  • very high resolution of 1 ppb in the trace range
  • cost-efficient service due to easy-to-replace membrane module and interior body
  • hygienic design
  • low cross-sensitivity to CO2
  • operation also in hazardous locations

High resolution of low oxygen concentrations, simple and cost-efficient sensor calibration in ambient air. No calibration gases. High signal stability, also in the presence of high CO2 partial pressures.

FDA-conforming material with extremely smooth polished surface. Simple maintenance due to modular design. Sterilizable, autoclavable, and CIP capable. Also suitable for hazardous locations.

Applications
Beverage filling (e.g. milk, beer), measurement in boiler feed water (detection limit 1 ppb)

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

Composition de la membrane: PTFE / silicone / PTFE, conforme à la FDA (armé d'un filet en acier)
Joint torique (en contact avec le milieu): Silicone (testé FDA & USP Classe VI)
Limite de détection: 1 ppb (3 ppb dans les liquides contenant du CO₂)
Paramètres de mesure: oxygène
Perm. temp range (measurement): 0 ... 80 °C
Permissible pressure range (measurement): 0,2 ... 6 bar absolu
Pièces de la sonde en contact avec le milieu: Acier inox 1.4404 (certificat de composition 3.1)
Principe de mesure: Ampérométrique
Précision: 1 % + 1 ppb (1 % +3 ppb dans les liquides contenant du CO₂)
Résistance mécanique à la pression: Max. 12 bar absolu
Signal dans l'air ambiant: 290 … 500 nA
Signal résiduel dans un milieu exempt d'O₂: ≤0,1% du signal dans l'air ambiant | Dans le CO2 : ≤ 0,01% du signal dans l'air ambiant
Sonde de température: CTN 22 kΩ
Temps de réponse à 25 °C (air –> N2): 98 % de la valeur finale < 90 s
Transmission du signal: numérique
Longueur : 320 mm
Tête enfichable: Memosens
Plage de mesure: pO₂  < 1,200 mbar
Protection contre les explosions: Oui
Flow dependence: ≤ 5 %
Temperature range (stability): –5 ... +121 °C (stérilisable à la vapeur / autoclavable)
Surface roughness: N 5 (RA < 0,4 μm)
Interior body incl. electrodes: Remplaçable (ZU 0568)

Téléchargements

Manuals

[3105] User Manual
SE707 Memosens Oxygen Sensor
Version 04
[16286] User Manual (DE, EN, KO)
Memosens Cable CA/MS
Version 09

Brochures

[13209] Brochure
Memosens - La solution complète pour des applications de mesure intelligentes.
[13395] Brochure
Sondes - Pour la mesure du pH/redox, de la conductivité et de l’oxygène. Numérique et analogique.

Fiches techniques

[3096] Fiche technique
Sonde d'oxygène SE707 Memosens
Description du produit | Caractéristiques techniques | Gamme de produits
[10145] Fiche technique
Accessoires pour sondes d'oxygène
Description du produit | Caractéristiques techniques | Gamme de produits

Certificats

[12831] IECEx Certificate of Conformity
Memosens Ex Sensors | Details see Document
Document No. IECEx BVS 16.0030X, issue No. 2 | 2024-02-23
Marking: Ex ia IIC T3/T4/T6 Ga
[12781] EU Declaration of Conformity (DE, EN, FR)
No. EU210706D | 2021-07-06
Memosens Measuring Cable Type CA/MS-...X.., CA/MS-...X..-L
[11064] EU Declaration of Conformity
No. EU210427A | 2021-04-27
Memosens Sensors | Types SE 5..X..-.MS., SE604X-MS**, SE605….., SE6**X**MS, SE7**…
[14685] Certificate of Conformity (FM)
No. FM17US0208X | 2019-05-27 | USA
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[12902] Confirmation / Bestätigung
Series SE706X/*-NMSN, SE707X/*-NMSN
No components of animal origin / Kein tierischer Ursprung
[14155] Declaration of Compliance 2.1 (DE, EN)
according to EN 10204 | gemäß EN 10204
[16639] Type Approval Certificate for Ex-Equipment (JA)
No. DEK19.0046X, Issue No. 0 (Japan)
SE5**X/*-*MSN | SE7**X/*-*MSN
[12826] EU-Type Examination Certificate (DEKRA)
Nr. BVS 16 ATEX E 037 X | 2024-02-20
Memosens-Ex-Sensors
[17559] Korean Safety Certificate
Ex ia IIC T3/T4/T6 Ga / 23-KA4BO-0104X
SE706X/*-NMSN;SE707X/*-NMSN
2023-02-21

Schémas de Contrôle

[14185] Control Drawing
Inductive Sensor-Cable Connection System Memosens
Zeichnungsnummer 214.410-240

Notre service

Utilisé dans les processus ou les applications

Étant donné que les générateurs de vapeur remplissent des fonctions critiques pour leurs applications et que leur indisponibilité ou leur remplacement entraînent des dépenses extrêmement élevées, il est crucial de prévenir les dommages causés par l’usure en surveillant correctement la qualité de l’eau.

Produits apparentés

Ignorer la galerie de produits

Articles de blog pertinents

pH and conductivity measurement in vaccine production

Pharmaceutical contract manufacturer relies on Knick's transmitters for modular production plants for Covid-19 vaccines.

Nouveau transmetteur Stratos Multi E461N avec Profinet

L'interface Profinet du nouveau transmetteur multiparamètres Stratos Multi E461N permet une communication continue des paramètres de process et une maintenance prédictive, du niveau du terrain jusqu'aux systèmes de contrôle des process usuels.

Stratos Multi E401X- Transmetteur multiparamètres pour zones Ex

Le nouveau Stratos Multi peut désormais être utilisé dans les zones Ex.

The Big Three of the Process Industry: HART, FF, Profibus

Our Knick multi-parameter analyzers are now available with Profibus and FF interfaces. Even for hazardous areas.