Stratos Pro A231X Multiparameter Transmitter | Memosens/Analog Sensors | Ex Zone 0/1 | Foundation Fieldbus
产品编号:
A231X
Description
Stratos Pro A231X Multiparameter Transmitter | Memosens/Analog Sensors | Ex Zone 0/1 | Foundation Fieldbus
2-wire analyzer (Foundation Fieldbus)
- Digital communication: FOUNDATION-Fieldbus
- Explosion protection: Zone 1 / Class 1 Division 1 (with sensor in Zone)
- Intuitive operation with color-coded user guidance
- IP 66/67, NEMA 4X protection
- Automatic sensor identification
- Sensor diagnostic with wear indication, remaining lifetime, CIP/SIP counter and adaptive calibration timer
- High-contrast widescreen display with colored backlighting
- Protective pane made of safety glass
- One analog input (4 ... 20 mA) e.g. for external pressure compensation
- Two parameter sets
- Two digital inputs:
- External HOLD activation
- External switching between parameter set
- Logbook (200 entries)
Outstanding properties
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
Wide Range of Functions
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value.
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value.
Zone 1 Explosion Protection
Stratos Pro is designed for operation in Zone 1 / Class 1 Division 1 hazardous areas (with the sensor in Zone 0). Operation in hazardous areas from –20 °C to +65 °C is possible. The devices are designed for gas and dust explosion protection (G/D) and can naturally also be used outdoors (type 4 enclosure, UV resistant).
Stratos Pro is designed for operation in Zone 1 / Class 1 Division 1 hazardous areas (with the sensor in Zone 0). Operation in hazardous areas from –20 °C to +65 °C is possible. The devices are designed for gas and dust explosion protection (G/D) and can naturally also be used outdoors (type 4 enclosure, UV resistant).
我们期待您的来信
联系我们
| permanently installed / portable: |
permanently installed
|
|---|---|
| 产品线: |
Stratos
Stratos Pro
|
| 外壳: |
PBT/PC 塑料外壳,玻璃纤维增强
|
| 显示屏: |
液晶显示屏,带彩色背光
|
| 测量参数: |
pH
pH/氧化还原
多参数
氧
氧化还原
电导率(接触式)
|
| 2 线制或 4 线制: |
2 线制
|
| 通道: |
单通道
|
| 通信(数字输出): |
Foundation Fieldbus
|
| 传感器连接: |
Memosens | 模拟
|
| 电流输出: |
无 mA 输出
|
| 防爆: |
1 号防爆区
是
|