Product added to compare
Product Compare added Product Compare

WG21 Repeater Power Supply | Input 4 … 20 mA | Integrated Power Supply | Ex | Transmission of HART signals

Description

WG21 Repeater Power Supply | Input 4 … 20 mA | Integrated Power Supply | Ex | Transmission of HART signals

For supply of intrinsically safe 2-wire transmitters and SMART transmitters

  • SMART transmission
    (Optional): Bidirectional point-to-point transmission of digital data according to the HART specification
  • High supply voltage and good hazardous area ratings:
    Universal use
  • Broad-range power supply:
    Just 2 versions for all mains voltages
  • Protective separation according to EN 61140
    Protection of maintenance staff and subsequent devices against excessively high voltages
  • 3-port isolation:
    Protection against incorrect measurements or damage to the equipment due to parasitic voltages
  • High transmission accuracy:
    Exact transmission of measured values
  • Explosion protection according to ATEX 
    Easy use in hazardous areas
  • Modular housing 22.5 mm
    Straightforward installation due to compact design
  • 5 year warranty

The WG 21 repeater power supply is used to supply intrinsically safe 2-wire transmitters. It supplies the transmitter with power and transmits the measurement signal to the output galvanically isolated and with high accuracy. In addition to the analog signal, the WG21 also optionally transmits data protocols for SMART transmitters (HART). It allows for bidirectional communication between the field device from every point of the wiring.

The high supply voltage, the good hazardous-area ratings and the broad-range power supply allow for universal use. Cables up to 1400 m in length can be used without any problems. Thanks to a new transformer-based transmission technique, the WG21 achieves an extraordinarily high transmission accuracy for hazardous-area applications. The encapsulation provides maximum operating safety, long-term stability, and disruptive strength even under extreme ambient conditions.

我们期待您的来信
联系我们

技术细节

是否防爆: Ex
标识: ATEX: II (1) G [EEx ia] IIC
通信(输出,数字): HART
产品类别: 通用隔离器 / 标准信号隔离器

下载

操作说明书

[4498] User Manual (DE, EN)
WG 21 A7 Repeater Power Supply
Version 03

数据手册

[4382] 数据表
WG 21
产品描述 | 规格 | 产品范围

证书

[5155] EU Declaration of Conformity (DE, EN, FR)
No. EU210706L | 2021-07-06
WG 21 A7, Opt. ...

我们的服务

在工艺或应用中使用

高压隔离放大器和变送器,用于采集和转换电流、电压、温度、转速、应变和电阻信号。
Knick 的电气测量技术为信号采集和转换以及电流、电压等测量提供多种解决方案。

相关产品

相关的博客文章

Stack and String Voltage Measurement in Electrolyzers and Fuel Cells

Voltage, current and temperature measurement in electrolyzers with P40000 series high voltage transducers

适用于 Knick 变送器的新型 30 mV 分流电阻

Knick 从现在起为其高压变送器的附件产品系列增添具有 30 mV 电压降的分流电阻
Innovations at InnoTrans 2024

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

P52000VPD 电压检测器能够可靠检测高达 4200 V 的直流电压

新型电压检测器 P52000VPD (Voltage Presence Detection) 能够可靠监控高压应用领域,在达到指定阈值时向下游设备控制器发送信号。

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

VariTrans A20340 – 仅需一个隔离放大器的标准信号倍增

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Pulse frequency conditioner for speed sensors

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

全球最小传感器,高达±2200 V

Knick的VariTrans P 40000系列能对从±50 mV到±3600 V的电压,以及从±100 mA到±20 kA的电流进行可靠测量。经过验证的ProLine系列现在已经扩展到包含传感器P42000D2,它安装在Din导轨上,模块设计紧凑,测量高达2200 V的直流电压。

宽范围电源对于直流电气测量的重要性

Knick生产的众多直流电气测量产品都包含通用的,也称为宽范围电源。这意味着它们将工作在一个相对较宽的电压范围窗口内,如20…253V,交流或直流。

Measuring Photovoltaic Degradation

Photovoltaic (PV) array degradation is an important aspect to consider for system design and installation.

Electrical Measurement Solutions: Control from 480 to 4800 Volts

Voltage and current transducers from Knick bring true control to electrical measurement applications across a wide-range of industries.

Benefits of High Voltage Transducers versus Instrument Transformers

When a need arises to step voltage in a circuit either up or down for purposes of power transmission or distribution, there is no doubt that transformers are essential.

分流器和霍尔效应的技术对比

在许多系统中,为了确保性能和安全,需要测量较大的直流电流。两个例子是静态励磁和轨道牵引动力。这些电流的测量通常采用两种主要原理之一:配有mV级变送器的分流器电阻或霍尔效应传感器来反馈。

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.