The ZU1475 is a rugged, high-isolation signal cable designed for safely connecting primary high voltage circuits to Knick transducers in the P29000, P40000, P44000, P45000, and P50000 series. Engineered for demanding industrial and railway environments, the ZU1475 provides reliable performance in the most challenging applications.

The cable supports up to 5400 V DC phase to ground and 9000 V DC phase to phase, with an 11 kV test voltage to ensure safe and accurate signal transmission. Its compact 4.5 mm diameter and 1.5 mm² cross-section make it ideal for tight panel installations where space is limited.

  • Rated for high-voltage DC/AC connections up to 9000 V DC / 6000 V AC
  • Stranded, tin-plated copper conductor
  • Low-capacitance (215 pF/m) and low resistance (13.7 Ω/km) for signal integrity
  • Meets EN 45545 (HL1…HL3) and NFPA 130 fire protection standards for rail applications
  • Operating temperature: –50 to +120°C
  • Includes: 2 cables, each approx. 2 meters

We look forward to hearing from you!
Contact Us

Technical details

Cable diameter: 4,5 mm ±0,1 mm
Rated voltage phase to ground: 5400 V DC / 3600 V AC
Signal cable length: Approx. 2 m
Function: Connection of primary high-voltage circuits with transducers
Test Voltage: 11 kV AC
Ambient operating temperature: –50 … 120 °C (–58 … 248 °F)

Downloads

Manuals

[102670] Accessories Manual (EN/DE)
ZU1475 HV Signal Cable
Version 01

Our service

Used in Process or Applications

Current and voltage measurement, as well as signal conversion in high-voltage environments in test benches for electric vehicles and charging infrastructure
Electrical measurement in DC traction power substations and on rolling stock; conversion and duplication of speed sensor signals on-board rail vehicles.
Thanks to their high isolation and reliability, the high-voltage transducers and signal conditioners from Knick have already proven themselves in many hydrogen applications.

Related Products

Skip product gallery
P29000 High Voltage Transducer / Transmitter | Calibrated and Switchable
P29000 High Voltage Transducer / Transmitter | Calibrated and Switchable

Input: 0 ... (±)30 mV up to 0 ... (±)100 V, 0 ... (±)100 V up to 0 ... (±)1000 V

Isolation AC/DC: up to 1,000 V

P41000 High Voltage Transducer / Transmitter | Calibrated and Switchable
P41000 High Voltage Transducer / Transmitter | Calibrated and Switchable

Input: 0 ... (±)50 mV up to 0 ... (±)100 V

Isolation AC/DC: up to 3,600 V

P41000 TRMS AC/DC High Voltage Transducer / Transmitter
P41000 TRMS AC/DC High Voltage Transducer / Transmitter

Input: 0 ... 10 V AC, 0 ... 50 mV AC

Isolation AC/DC: up to 3,600 V

P41000AG High Voltage Transducer / Transmitter | Calibrated and Switchable
P41000AG High Voltage Transducer / Transmitter | Calibrated and Switchable

Input: 0 ... (±)30/330 mV up to 0 ... (±)120/1320 mV

Isolation AC/DC: up to 3,600 V

P42000 High Voltage Transducer / Transmitter | Calibrated and Switchable
P42000 High Voltage Transducer / Transmitter | Calibrated and Switchable

Input: 0 ... (±)100 V up to 0 ... (±)3600 V

Isolation AC/DC: 2,200 V, up to 3,600 V

P42000 TRMS AC/DC High Voltage Transducer / Transmitter
P42000 TRMS AC/DC High Voltage Transducer / Transmitter

Input: 0 ... 3600 V AC, 0 ... 10 V AC

Isolation AC/DC: 2,200 V, up to 3,600 V

P43000 High Voltage Transducer / Transmitter | Calibrated and Switchable
P43000 High Voltage Transducer / Transmitter | Calibrated and Switchable

Input: 0 ... (±)0.1 A upt to 0 ... (±)5 A

Isolation AC/DC: up to 3,600 V

P43000 TRMS AC/DC High Voltage Transducer / Transmitter
P43000 TRMS AC/DC High Voltage Transducer / Transmitter

Input: 0 ... 5 A AC, 0 ... 100 mA AC

Isolation AC/DC: up to 3,600 V

P44000 Temperature Transmitter with High Insulation | Pt100 Sensor Input
P44000 Temperature Transmitter with High Insulation | Pt100 Sensor Input

Input: 0 ... 100 °C, 0 ... 300 °C, 0 ... 200 °C

Isolation AC/DC: up to 2,000 V, up to 6,600 V

P45000 High Voltage Transducer / Transmitter | SIL 2/SIL 3 Functional Safety
P45000 High Voltage Transducer / Transmitter | SIL 2/SIL 3 Functional Safety

Input: 0 ... (±)2000 V, 0 ... (±)1000 V, 0 ... (±)2800 V, 0 ... (±)3000 V, Overrange up to 150 %, 0 ... (±)500 V, 0 ... (±)750 V, 0 ... (±)1500 V

Isolation AC/DC: up to 3,600 V AC, 4,800 V DC