Passer au contenu principal Passer à la recherche Passer à la navigation principale

Résistances shunt | À capacité de surcharge élevée | Immunes contre les champs externes

Description

Résistances shunt | À capacité de surcharge élevée | Immunes contre les champs externes

Precise and long-term stable measurement of direct current

  • For currents up to 20 kA
    with a standard program from 10 A to 8 kA

  • Low heat loss and low space requirement
    due to small measuring voltages from 30 mV

  • Precise measurement
    with accuracy classes 0.2 and 0.5

  • Special versions for energy measuring systems on rail vehicles
    according to EN 50463

  • High overload capacity
    without residual measurement failure

  • No influence from current peaks or neighboring cables
    due to the measuring principle

  • Low temperature coefficient
    and thus small measurement failure due to temperature influences

  • Safe electrical isolation and short response times
    through a combination with measuring transducers from Knick

  • Galvanic isolation between power section and control
    up to 3.6 kV working voltage / 15 kV test voltage

  • Conversion to standard signals
    ±20 mA, ±10 V, 4 to 20 mA

  • 5 year guarantee

The meticulously produced shunt resistors feature resistor rods made of manganin with low self heating and an exceptionally low temperature coefficient. The variants with a rated voltage drop of 30 mV distinguish themselves from the 50 mV or 60 mV versions thanks to more compact dimensions and significantly lower power dissipation, which greatly reduces the effort required for electrical enclosure cooling. Knick’s transducers and signal conditioners from the P41000, P51000, P29000, P27000, and BL591 series, which are adapted optimally to the shunt resistors, are available for current measurement.

The shunt resistors and associated shunt isolators achieve very good long-term stability, which guarantees the specified accuracy over the normal periods of application of many years. Current peaks do not cause any offset or drift. Protection equipment based on current measurement benefits from the reliability and long-term stability of the measurement and achieves a particularly high level of safety performance.

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

Fonction: Résistance shunt pour la mesure du courant
Entrée: 0 ... 1 A jusqu'à 0 ... 20 kA
Sortie: 0 ... 30 mV, 0 ... 50 mV, 0 ... 60 mV
Température ambiante de service: -10 ... 55 °C
Dimensions (l x L x H): Selon la valeur saisie
Catégorie de produits: Amplificateur séparateur haute tension, Séparateur universel / séparateur de signaux normalisés

Téléchargements

Brochures

[14160] Brochure
Aperçu des produits Technologie d'interface

Fiches techniques

[903] Data Sheet
Shunt Resistor for Direct Current Measurements from 1 A to 20 kA
Product Description | Specifications | Product Range
Version 03

Certificats

[13916] EU Declaration of Conformity (DE, EN, FR)
No. EU170803A | 2017-08-03
Maconic M...S, M...HS

Installation guides

[14541] Installation Guide (DE, EN)
Sealing Maconic Shunt Resistors / Plombensicherung von Maconic Shunt-Widerständen
Version 01

Notre service

Utilisé dans les processus ou les applications

Amplificateurs séparateurs haute tension et convertisseurs de mesure pour l’acquisition et la conversion de signaux de courant, de tension, de température, de régime, de dilatation et de résistance.

Articles de blog pertinents

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.