Passer au contenu principal

A26000 Universal Isolated Signal Conditioner | Input 0…±20 mA or 0…±10 V | Current and voltage measurement

Description

A26000 Universal Isolated Signal Conditioner | Input 0…±20 mA or 0…±10 V | Current and voltage measurement

The specialist for ±10 V and ±20 mA. With calibrated range selection and broad-range power supply.

  • Flexible and extremely precise
    Calibrated range selection without complicated readjustments
  • Broad-range power supply
    VariPower 20 … 253 V AC/DC
  • Compact design
    12.5 mm modular housing; up to 80 active isolators per meter of mounting rail
  • Quick and easy configuration
    Housing can be easily opened
  • Pluggable screw terminals
    Simple, time-saving assembly and prewiring of enclosures
  • 3-port separation
    Protection against incorrect measurements or damage
  • Maximum accuracy
  • Specific test report
    Following EN 10204 2.2
  • Protective separation
    according to EN 61140 protects against unpermitted high voltages
  • Maximum reliability
    No repair and failure costs
  • 5-year warranty 

Isolation amplifier for the transmission and conversion of standard 0 to ±20 mA and 0 to ±10 V bipolar signals frequently used in industry, for example, for speed monitoring using tachogenerators.

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

Séparation des potentiels CA/CC: Jusqu’à 1 000
Entrée: 0 ... (±)10 V, 0 ... (±)20 mA
Sortie: 0 ... (±)10 V, 0 ... (±)20 mA
Tension d'essai: 4 kV CA
Alimentation en tension: 22 ... 230 V CA/CC
Fréquence seuil: Fréquence seuil de 5 kHz ou 10 Hz
Température ambiante de service: –10 ... 70 °C
Dimensions (l x L x H): 12,5 x 99 x 111 mm
Caractéristiques particulières: Configuration simple avec un interrupteur DIP, Même après la commutation d’une plage, les plages de transmission restent calibrées et n’ont pas à être réajustées, Spécialement pour la conversion précise et l’isolation galvanique des signaux bipolaires
Standards: UL 61010-1
Catégorie de produits: Séparateur universel / séparateur de signaux normalisés

Téléchargements

Manuals

[410] User Manual (DE, EN, FR)
A26000
Version 07

Fiches techniques

[399] Fiche technique
A26000
Description du produit | Caractéristiques techniques | Gamme de produits

Certificats

[11164] EU Declaration of Conformity (DE, EN, FR)
No. EU220125J | 2022-01-25
A260**F1/H1 | P150**F1/H1 | B130**F1
[11745] DNVGL Type Approval Certificate
No. TAA00002H8
Issue No. 2
P150**H1, P150**F1, A260**F1, A260**H1
[11437] Certificate of Compliance (UL)
No. 2019-11-22-E340287 (ZT231124D)
Process Control Equipment, Electrical
Series B130** P150** A260** BL513

Software

[12154] Software (.zip)
ePLAN P8 Produktmakros
[11876] Knick Produktmakros (.pdf)
ePLAN Electric P8

Notre service

Utilisé dans les processus ou les applications

Amplificateurs séparateurs haute tension et convertisseurs de mesure pour l’acquisition et la conversion de signaux de courant, de tension, de température, de régime, de dilatation et de résistance.
Amplificateurs séparateurs haute tension stables à long terme, convertisseurs de mesure et multiplicateurs de signaux pour les applications exigeantes

Produits apparentés

Articles de blog pertinents

Stack and String Voltage Measurement in Electrolyzers and Fuel Cells

Voltage, current and temperature measurement in electrolyzers with P40000 series high voltage transducers

Des nouvelles résistances shunt de 30 mV pour les convertisseurs de mesure de Knick

Knick agrandit dès à présent sa gamme d’accessoires prévue pour les convertisseurs haute tension de résistances shunt avec chute de tension de 30 mV
Innovations at InnoTrans 2024

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

Le détecteur de tension P52000VPD assure une détection fiable des tensions jusqu'à 4200 V DC

Le nouveau détecteur de tension P52000VPD (Voltage Presence Detection) assure une surveillance fiable des zones à haute tension et envoie un signal à la commande de l'installation en aval lorsqu'une valeur seuil définie est atteinte.

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

VariTrans A20340 - Multiplication des signaux normalisés dans un seul amplificateur séparateur

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Convertisseur de fréquence pour capteurs de vitesse

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

Le convertisseur le plus compact du monde jusqu’à ±2200 V

La série VariTrans P 40000 de Knick permet de réaliser des mesures de tension fiables de ±50 mV jusqu’à ±3600 V et des mesures de courant de ±100 mA jusqu’à ±20 kA. Cette série ProLine éprouvée accueille à présent le convertisseur P42000D2.

L’importance des systèmes d’alimentation à large spectre pour les mesures électriques DC

De nombreux instruments de mesure électrique DC fabriqués par Knick comprennent une alimentation universelle, ou à large spectre. Cela signifie qu’ils fonctionnent avec un spectre relativement large de tension, par exemple 20…253 V, AC ou DC.

Mesure de la dégradation photovoltaïque

L’ampleur de la dégradation photovoltaïque (PV) est un élément important à prendre en compte pour la conception et l’installation de systèmes. Des facteurs tels que la météo et l’exposition aux UV contribuent au déclin de la performance.

Solutions de mesures électriques : Contrôles de 480 à 4800 Volts

Les transducteurs de tension de Knick permettent un contrôle réel aux applications de mesures électriques dans un vaste éventail de secteurs.

Les avantages des transducteurs haute tension par rapport aux transformateurs de mesure

Les transformateurs ont longtemps été considérés comme des composants importants des systèmes électriques. Il ne fait aucun doute que ces appareils sont essentiels.

Shunt Resistor versus Hall Effect Technology

There are many systems where measurement of large DC currents are needed for performance and safety.

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.